TY - JOUR
T1 - Why STAN might not be dead
AU - Xodo, Serena
AU - Saccone, Gabriele
AU - Schuit, Ewoud
AU - Amer-Wåhlin, Isis
AU - Berghella, Vincenzo
PY - 2016/11/2
Y1 - 2016/11/2
N2 - Recently, a meta-analysis, including 26 526 laboring vertex singletons at term, summarized all available level-1 data from six high-quality randomized clinical trials (RCTs) on the use of ST analysis (STAN) during labor as an adjunct to conventional intrapartum fetal heart rate monitoring. The meta-analysis showed that STAN did not improve perinatal outcomes or decrease cesarean deliveries. Nonetheless, there are still reasons to believe STAN may have a role in the future research on intrapartum fetal monitoring. Out of six trials included in the meta-analysis, two included all cephalic singletons in labor, and four enrolled only high-risk pregnant women. This combination of both low- and high-risk populations may have distorted the potential impact of STAN. The test for heterogeneity between both subgroups was found to be statistically significant, indicating that the effect of STAN was different in high-risk women compared to a combination of both low- and high-risk women. Furthermore, the classifications of the fetal heart rate patterns used in the included randomized trials were different. Last but not least, despite >26 000 women with singleton gestations were included in the meta-analysis, the evidence still suffers from a lack of power, especially for subgroup analyses. In summary, while the level-1 data so far indicate overall no perinatal benefit of adding STAN to conventional intrapartum fetal heart rate monitoring for the outcomes most of interest, several issues point to the fact that more research is needed before the STAN technology can be deemed of no value for fetal monitoring in labor.
AB - Recently, a meta-analysis, including 26 526 laboring vertex singletons at term, summarized all available level-1 data from six high-quality randomized clinical trials (RCTs) on the use of ST analysis (STAN) during labor as an adjunct to conventional intrapartum fetal heart rate monitoring. The meta-analysis showed that STAN did not improve perinatal outcomes or decrease cesarean deliveries. Nonetheless, there are still reasons to believe STAN may have a role in the future research on intrapartum fetal monitoring. Out of six trials included in the meta-analysis, two included all cephalic singletons in labor, and four enrolled only high-risk pregnant women. This combination of both low- and high-risk populations may have distorted the potential impact of STAN. The test for heterogeneity between both subgroups was found to be statistically significant, indicating that the effect of STAN was different in high-risk women compared to a combination of both low- and high-risk women. Furthermore, the classifications of the fetal heart rate patterns used in the included randomized trials were different. Last but not least, despite >26 000 women with singleton gestations were included in the meta-analysis, the evidence still suffers from a lack of power, especially for subgroup analyses. In summary, while the level-1 data so far indicate overall no perinatal benefit of adding STAN to conventional intrapartum fetal heart rate monitoring for the outcomes most of interest, several issues point to the fact that more research is needed before the STAN technology can be deemed of no value for fetal monitoring in labor.
KW - Cardiotocography
KW - delivery
KW - labor
KW - nonstress test
KW - STAN
UR - http://www.scopus.com/inward/record.url?scp=84994073339&partnerID=8YFLogxK
U2 - 10.1080/14767058.2016.1247263
DO - 10.1080/14767058.2016.1247263
M3 - Article
C2 - 27734746
AN - SCOPUS:84994073339
SN - 1476-7058
SP - 1
EP - 3
JO - Journal of Maternal-fetal & Neonatal Medicine
JF - Journal of Maternal-fetal & Neonatal Medicine
ER -