TY - JOUR
T1 - Volumetric response beyond six months of cardiac resynchronization therapy and clinical outcome
AU - van t Sant, J
AU - Fiolet, Aernoud T L
AU - Ter Horst, Iris A H
AU - Cramer, MJ
AU - Mastenbroek, Mirjam H.
AU - Van Everdingen, Wouter M.
AU - Mast, TP
AU - Doevendans, Pieter A.
AU - Versteeg, Henneke
AU - Meine, Mathias
PY - 2015/5/1
Y1 - 2015/5/1
N2 - Aims: Response to cardiac resynchronization therapy (CRT) is often assessed six months after implantation. Our objective was to assess the number of patients changing from responder to non-responder between six and 14 months, so-called late non-responders, and compare them to patients who were responder both at six and 14 months, so-called stable responders. Furthermore, we assessed predictive values of six and 14-month response concerning clinical outcome. Methods: 105 patients eligible for CRT were enrolled. Clinical, laboratory, ECG, and echocardiographic parameters and patient-reported health status (Kansas City Cardiomyopathy Questionnaire [KCCQ]) were assessed before, and six and 14 months after implantation. Response was defined as ≥15% LVESV decrease as compared to baseline. Major adverse cardiac events (MACE) were registered until 24 months after implantation. Predictive values of six and 14-month response for MACE were examined. Results: In total, 75 (71%) patients were six-month responders of which 12 (16%) patients became late non-responder. At baseline, late non-responders more often had ischemic cardiomyopathy and atrial fibrillation, higher BNP and less dyssynchrony compared to stable responders. At six months, late non-responders showed significantly less LVESV decrease, and higher creatinine levels. Mean KCCQ scores of late non-responders were lower than those of stable responders at every time point, with the difference being significant at 14 months. The 14 months response was a better predictor of MACE than six months response. Conclusions: The assessment of treatment outcomes after six months of CRT could be premature and response rates beyond might better correlate to long-term clinical outcome.
AB - Aims: Response to cardiac resynchronization therapy (CRT) is often assessed six months after implantation. Our objective was to assess the number of patients changing from responder to non-responder between six and 14 months, so-called late non-responders, and compare them to patients who were responder both at six and 14 months, so-called stable responders. Furthermore, we assessed predictive values of six and 14-month response concerning clinical outcome. Methods: 105 patients eligible for CRT were enrolled. Clinical, laboratory, ECG, and echocardiographic parameters and patient-reported health status (Kansas City Cardiomyopathy Questionnaire [KCCQ]) were assessed before, and six and 14 months after implantation. Response was defined as ≥15% LVESV decrease as compared to baseline. Major adverse cardiac events (MACE) were registered until 24 months after implantation. Predictive values of six and 14-month response for MACE were examined. Results: In total, 75 (71%) patients were six-month responders of which 12 (16%) patients became late non-responder. At baseline, late non-responders more often had ischemic cardiomyopathy and atrial fibrillation, higher BNP and less dyssynchrony compared to stable responders. At six months, late non-responders showed significantly less LVESV decrease, and higher creatinine levels. Mean KCCQ scores of late non-responders were lower than those of stable responders at every time point, with the difference being significant at 14 months. The 14 months response was a better predictor of MACE than six months response. Conclusions: The assessment of treatment outcomes after six months of CRT could be premature and response rates beyond might better correlate to long-term clinical outcome.
KW - LEFT-VENTRICULAR DYSFUNCTION
KW - BRAIN NATRIURETIC PEPTIDE
KW - SEPTAL REBOUND STRETCH
KW - HEART-FAILURE
KW - HEALTH-STATUS
KW - REVERSE
KW - SURVIVAL
KW - PREDICTOR
KW - MORTALITY
KW - STATEMENT
UR - https://www.scopus.com/pages/publications/84929340764
U2 - 10.1371/journal.pone.0124323
DO - 10.1371/journal.pone.0124323
M3 - Article
C2 - 25933068
AN - SCOPUS:84929340764
SN - 1932-6203
VL - 10
JO - PLoS ONE [E]
JF - PLoS ONE [E]
IS - 5
M1 - e0124323
ER -