TY - JOUR
T1 - Troubled Judging of Bronchus Compression Due to Contrast-Filled Balloon in Three-Dimensional Rotational Angiography
AU - Moerdijk, Anouk S.
AU - Breur, Johannes M.P.J.
AU - Molenschot, Mirella M.C.
AU - Krings, Gregor J.
N1 - Publisher Copyright:
© 2021, The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
PY - 2022/3
Y1 - 2022/3
N2 - Three-dimensional rotational angiography (3DRA) is a suitable technique to detect the risk of left main bronchus (LMB) compression during left pulmonary artery (LPA) stenting in partial cavopulmonary connection and total cavopulmonary connection (TCPC). We report on a case of a 4-year-old boy with hypoplastic left heart syndrome and TCPC in which 3DRA and bronchoscopy gave conflicting information on airway patency during balloon interrogation. The balloon with high contrast concentration created a severe artifact impeding visibility of the LMB. Simultaneous flexible bronchoscopy revealed an unobstructed LMB. Repeated 3DRAs with lower contrast concentration had no artifact and showed a patent airway in accordance with the bronchoscopy. Conventional LPA stenting was performed without indication for stent ovalization. The benefit of low contrast concentration in the interrogation balloon was demonstrated in a second case of an 11-year-old boy with TCPC. The margins of the LPA and LMB were clearly visible without blank-out artifact. Oval stent procedure was necessary to prevent LMB compression. When 3DRA is used for vessel–airway interrogation, the balloon contrast concentration should be low in order to avoid artifacts. When in doubt, simultaneous flexible bronchoscopy can overcome the dilemma in airway judgment.
AB - Three-dimensional rotational angiography (3DRA) is a suitable technique to detect the risk of left main bronchus (LMB) compression during left pulmonary artery (LPA) stenting in partial cavopulmonary connection and total cavopulmonary connection (TCPC). We report on a case of a 4-year-old boy with hypoplastic left heart syndrome and TCPC in which 3DRA and bronchoscopy gave conflicting information on airway patency during balloon interrogation. The balloon with high contrast concentration created a severe artifact impeding visibility of the LMB. Simultaneous flexible bronchoscopy revealed an unobstructed LMB. Repeated 3DRAs with lower contrast concentration had no artifact and showed a patent airway in accordance with the bronchoscopy. Conventional LPA stenting was performed without indication for stent ovalization. The benefit of low contrast concentration in the interrogation balloon was demonstrated in a second case of an 11-year-old boy with TCPC. The margins of the LPA and LMB were clearly visible without blank-out artifact. Oval stent procedure was necessary to prevent LMB compression. When 3DRA is used for vessel–airway interrogation, the balloon contrast concentration should be low in order to avoid artifacts. When in doubt, simultaneous flexible bronchoscopy can overcome the dilemma in airway judgment.
KW - 3D rotational angiography
KW - Bronchus compression
KW - Cardiac catheterization
KW - Congenital heart defects
KW - Hypoplastic left heart syndrome
KW - Pulmonary artery stenting
UR - http://www.scopus.com/inward/record.url?scp=85123118413&partnerID=8YFLogxK
U2 - 10.1007/s00246-021-02775-y
DO - 10.1007/s00246-021-02775-y
M3 - Article
C2 - 35034158
SN - 0172-0643
VL - 43
SP - 704
EP - 708
JO - Pediatric Cardiology
JF - Pediatric Cardiology
IS - 3
ER -