Treatment of giant and large internal carotid artery aneurysms with a high-flow replacement bypass using the excimer laser-assisted nonocclusive anastomosis technique

Tristan P.C. Van Doormaal*, Albert Van Der Zwan, Bon H. Verweij, David J. Langer, Cornells A.F. Tulleken

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

27 Citations (Scopus)

Abstract

OBJECTIVE: To define the clinical value of the high-flow replacement bypass using the excimer laser-assisted nonocclusive anastomosis technique in the treatment of patients with a noncoilable, nonclippable giant or large intracranial aneurysm of the internal carotid artery (ICA). METHODS: We studied 34 patients with a giant intracranial aneurysm of the ICA proximal to its bifurcation who were treated with an extracranial-intercranial high-flow replacement bypass in our hospital between 1999 and 2004. We retrospectively collected data for patient characteristics, operative aspects, complications, and functional health scores using the modified Rankin scale. Long-term data were updated by questionnaire and telephone survey. Mean long-term follow-up period was 3.3 years (range, 0.6-5.6 yr). RESULTS: We were able to construct a patent bypass in 33 out of 34 patients (97%). In six patients (17%), we needed two bypass attempts. In one patient (3%), the bypass was technically impossible. After bypass construction, we occluded the ICA during or after surgery in 32 patients (94%), causing aneurysm thrombosis in all of these patients. A fatal complication occurred in two patients (6%) before we could occlude the ICA. A nonfatal complication occurred in seven patients (21%). In the long term, 25 patients (74%) had a favorable outcome and 27 patients (79%) were independent (modified Rankin scale, <3). CONCLUSION: This study shows that the excimer laser-assisted nonocclusive anastomosis high-flow replacement bypass, which provides maximum brain protection because of its nonocclusive character, is a reliable and effective method to treat these otherwise untreatable patients.

Original languageEnglish
Pages (from-to)SHC1411-SHC1417
JournalNeurosurgery
Volume62
Issue number6 SUPPL.
DOIs
Publication statusPublished - Jun 2008

Keywords

  • Excimer laser-assisted nonocclusive anastomosis bypass surgery
  • Giant aneurysm
  • High-flow replacement bypass
  • Internal carotid artery

Fingerprint

Dive into the research topics of 'Treatment of giant and large internal carotid artery aneurysms with a high-flow replacement bypass using the excimer laser-assisted nonocclusive anastomosis technique'. Together they form a unique fingerprint.

Cite this