TY - JOUR
T1 - The SABRE Trial (Sirolimus Angioplasty Balloon for Coronary In-Stent Restenosis)
T2 - Angiographic Results and 1-Year Clinical Outcomes
AU - Verheye, Stefan
AU - Vrolix, Mathias
AU - Kumsars, Indulis
AU - Erglis, Andrejs
AU - Sondore, Dace
AU - Agostoni, Pierfrancesco
AU - Cornelis, Kristoff
AU - Janssens, Luc P F
AU - Maeng, Michael
AU - Slagboom, Ton
AU - Amoroso, Giovanni
AU - Jensen, Lisette Okkels
AU - Granada, Juan F
AU - Stella, Pieter
N1 - Publisher Copyright:
© 2017 American College of Cardiology Foundation
PY - 2017/10/23
Y1 - 2017/10/23
N2 - Objectives The aim of this first-in-human study was to assess the safety and effectiveness of the Virtue sirolimus-eluting balloon in a cohort of patients with in-stent restenosis (ISR). Background Angioplasty balloons coated with the cytotoxic drug paclitaxel have been widely used for ISR treatment. The Virtue angioplasty balloon (Caliber Therapeutics, New Hope, Pennsylvania) delivers sirolimus in a nanoencapsulated liquid formulation. This clinical trial is the first to examine a sirolimus-eluting balloon for ISR. Methods In this prospective, single-arm feasibility study at 9 European centers, 50 ISR patients were treated with the Virtue balloon. Angiographic measurements at 6 months are reported, along with 12-month clinical follow-up. Results Procedural success in the intention-to-treat population was 100%. The primary safety endpoint was target lesion failure (TLF) (cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization) assessed at 30 days (0%, n = 50). The primary performance endpoint was in-segment late lumen loss (LLL) at 6 months (0.31 ± 0.52 mm; n = 47). Secondary 6-month endpoints include binary restenosis (19.1%), diameter stenosis (30.3 ± 19.9%), and major adverse cardiac events (MACE) (10.2%, n = 49). In the 36-patient per-protocol population (excluding major protocol violations and previously stented ISR), LLL was 0.12 ± 0.33 mm at 6 months. Clinical outcomes at 1 year for the intention-to-treat group were 12.2% TLF and 14.3% MACE and for the per-protocol population were 2.8% TLF and 2.8% MACE. Conclusions This first-in-human study showed excellent procedural success for the Virtue sirolimus-eluting angioplasty balloon, 6-month LLL rates in line with current stent-free ISR treatment options, and clinical outcomes that warrant further evaluation in dedicated randomized studies.
AB - Objectives The aim of this first-in-human study was to assess the safety and effectiveness of the Virtue sirolimus-eluting balloon in a cohort of patients with in-stent restenosis (ISR). Background Angioplasty balloons coated with the cytotoxic drug paclitaxel have been widely used for ISR treatment. The Virtue angioplasty balloon (Caliber Therapeutics, New Hope, Pennsylvania) delivers sirolimus in a nanoencapsulated liquid formulation. This clinical trial is the first to examine a sirolimus-eluting balloon for ISR. Methods In this prospective, single-arm feasibility study at 9 European centers, 50 ISR patients were treated with the Virtue balloon. Angiographic measurements at 6 months are reported, along with 12-month clinical follow-up. Results Procedural success in the intention-to-treat population was 100%. The primary safety endpoint was target lesion failure (TLF) (cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization) assessed at 30 days (0%, n = 50). The primary performance endpoint was in-segment late lumen loss (LLL) at 6 months (0.31 ± 0.52 mm; n = 47). Secondary 6-month endpoints include binary restenosis (19.1%), diameter stenosis (30.3 ± 19.9%), and major adverse cardiac events (MACE) (10.2%, n = 49). In the 36-patient per-protocol population (excluding major protocol violations and previously stented ISR), LLL was 0.12 ± 0.33 mm at 6 months. Clinical outcomes at 1 year for the intention-to-treat group were 12.2% TLF and 14.3% MACE and for the per-protocol population were 2.8% TLF and 2.8% MACE. Conclusions This first-in-human study showed excellent procedural success for the Virtue sirolimus-eluting angioplasty balloon, 6-month LLL rates in line with current stent-free ISR treatment options, and clinical outcomes that warrant further evaluation in dedicated randomized studies.
KW - drug-eluting balloon
KW - extended release
KW - in-stent restenosis
KW - porous angioplasty balloon
KW - sirolimus nanoparticle
UR - http://www.scopus.com/inward/record.url?scp=85030714148&partnerID=8YFLogxK
U2 - 10.1016/j.jcin.2017.06.021
DO - 10.1016/j.jcin.2017.06.021
M3 - Article
C2 - 28964764
SN - 1936-8798
VL - 10
SP - 2029
EP - 2037
JO - JACC. Cardiovascular Interventions
JF - JACC. Cardiovascular Interventions
IS - 20
ER -