TY - JOUR
T1 - Test-retest variability of volumetric right ventricular measurements using real-time three-dimensional echocardiography
AU - van der Zwaan, H.B.
AU - Geleijnse, M.L.
AU - Soliman, Ol
AU - McGhie, J.S.
AU - Wiegers-Groeneweg, E.J.
AU - Helbing, W.A.
AU - Roos-Hesselink, J.W.
AU - Meijboom, F.J.
N1 - Copyright © 2011 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
PY - 2011/6
Y1 - 2011/6
N2 - BACKGROUND: Substantial variability in sequential echocardiographic right ventricular (RV) quantification may exist. Interobserver and intraobserver values are well known, but acquisition (test-retest) variability has been rarely assessed. The objective of this study was to determine the test-retest variability of sequential RV volume and ejection fraction (EF) measurements by real-time three-dimensional echocardiography in patients with congenital heart disease and healthy controls.METHODS: Twenty-eight participants (21 patients with congenital heart disease, seven healthy controls; mean age, 30 ± 14 years; 43% men) underwent a series of three echocardiographic studies. To obtain interobserver and intraobserver test-retest variability, two sonographers acquired sequential RV data sets in each participant during one outpatient visit. RV volumetric quantification was done using semiautomated three-dimensional border detection. The variability data were analyzed using correlation coefficients, Bland-Altman analysis, and coefficients of variation.RESULTS: Absolute mean differences for sequential intraobserver acquisitions were 12 ± 12 mL for end-diastolic volume, 7 ± 6 mL for end-systolic volume, and 4 ± 3% for EF. Interobserver and intraobserver test-retest variability, respectively, were 7% and 7% for RV end-diastolic volume, 14% and 7% for end-systolic volume, and 8% and 6% for EF.CONCLUSIONS: Good test-retest variability, besides the practical nature of real-time three-dimensional echocardiography for RV volume and EF assessment, makes it a valuable technique for serial follow-up. Although it may be challenging to diminish all factors that can influence echocardiographic examination for serial follow-up, standardization of RV size and functional measurements should be a goal to produce more interchangeable data.
AB - BACKGROUND: Substantial variability in sequential echocardiographic right ventricular (RV) quantification may exist. Interobserver and intraobserver values are well known, but acquisition (test-retest) variability has been rarely assessed. The objective of this study was to determine the test-retest variability of sequential RV volume and ejection fraction (EF) measurements by real-time three-dimensional echocardiography in patients with congenital heart disease and healthy controls.METHODS: Twenty-eight participants (21 patients with congenital heart disease, seven healthy controls; mean age, 30 ± 14 years; 43% men) underwent a series of three echocardiographic studies. To obtain interobserver and intraobserver test-retest variability, two sonographers acquired sequential RV data sets in each participant during one outpatient visit. RV volumetric quantification was done using semiautomated three-dimensional border detection. The variability data were analyzed using correlation coefficients, Bland-Altman analysis, and coefficients of variation.RESULTS: Absolute mean differences for sequential intraobserver acquisitions were 12 ± 12 mL for end-diastolic volume, 7 ± 6 mL for end-systolic volume, and 4 ± 3% for EF. Interobserver and intraobserver test-retest variability, respectively, were 7% and 7% for RV end-diastolic volume, 14% and 7% for end-systolic volume, and 8% and 6% for EF.CONCLUSIONS: Good test-retest variability, besides the practical nature of real-time three-dimensional echocardiography for RV volume and EF assessment, makes it a valuable technique for serial follow-up. Although it may be challenging to diminish all factors that can influence echocardiographic examination for serial follow-up, standardization of RV size and functional measurements should be a goal to produce more interchangeable data.
KW - Adult
KW - Case-Control Studies
KW - Echocardiography, Three-Dimensional
KW - Female
KW - Heart Defects, Congenital
KW - Humans
KW - Male
KW - Prospective Studies
KW - Reproducibility of Results
KW - Stroke Volume
KW - Ventricular Dysfunction, Right
U2 - 10.1016/j.echo.2011.02.007
DO - 10.1016/j.echo.2011.02.007
M3 - Article
C2 - 21440417
SN - 0894-7317
VL - 24
SP - 671
EP - 679
JO - Journal of the American Society of Echocardiography
JF - Journal of the American Society of Echocardiography
IS - 6
ER -