Targeted MS Assay Predicting Tamoxifen Resistance in Estrogen-Receptor-Positive Breast Cancer Tissues and Sera

Tommaso De Marchi, Erik Kuhn, Lennard J Dekker, Christoph Stingl, Rene B H Braakman, Mark Opdam, Sabine C Linn, Fred C G J Sweep, Paul N Span, Theo M Luider, John A Foekens, John W M Martens, Steven A Carr, Arzu Umar

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

We recently reported on the development of a 4-protein-based classifier (PDCD4, CGN, G3BP2, and OCIAD1) capable of predicting outcome to tamoxifen treatment in recurrent, estrogen-receptor-positive breast cancer based on high-resolution MS data. A precise and high-throughput assay to measure these proteins in a multiplexed, targeted fashion would be favorable to measure large numbers of patient samples to move these findings toward a clinical setting. By coupling immunoprecipitation to multiple reaction monitoring (MRM) MS and stable isotope dilution, we developed a high-precision assay to measure the 4-protein signature in 38 primary breast cancer whole tissue lysates (WTLs). Furthermore, we evaluated the presence and patient stratification capabilities of our signature in an independent set of 24 matched (pre- and post-therapy) sera. We compared the performance of immuno-MRM (iMRM) with direct MRM in the absence of fractionation and shotgun proteomics in combination with label-free quantification (LFQ) on both WTL and laser capture microdissected (LCM) tissues. Measurement of the 4-proteins by iMRM showed not only higher accuracy in measuring proteotypic peptides (Spearman r: 0.74 to 0.93) when compared with MRM (Spearman r: 0.0 to 0.76) but also significantly discriminated patient groups based on treatment outcome (hazard ratio [HR]: 10.96; 95% confidence interval [CI]: 4.33 to 27.76; Log-rank P < 0.001) when compared with LCM (HR: 2.85; 95% CI: 1.24 to 6.54; Log-rank P = 0.013) and WTL (HR: 1.16; 95% CI: 0.57 to 2.33; Log-rank P = 0.680) LFQ-based predictors. Serum sample analysis by iMRM confirmed the detection of the four proteins in these samples. We hereby report that iMRM outperformed regular MRM, confirmed our previous high-resolution MS results in tumor tissues, and has shown that the 4-protein signature is measurable in serum samples.

Original languageEnglish
Pages (from-to)1230–1242
JournalJournal of Proteome Research
Volume15
Issue number4
DOIs
Publication statusPublished - 9 Mar 2016

Fingerprint

Dive into the research topics of 'Targeted MS Assay Predicting Tamoxifen Resistance in Estrogen-Receptor-Positive Breast Cancer Tissues and Sera'. Together they form a unique fingerprint.

Cite this