TY - JOUR
T1 - Sutureless versus Hand-Sewn Coronary Anastomoses
T2 - A Systematic Review and Meta-Analysis
AU - Hoogewerf, Marieke
AU - Schuurkamp, Jeroen
AU - Kelder, Johannes C.
AU - Jacobs, Stephan
AU - Doevendans, Pieter A.
N1 - Publisher Copyright:
© 2022 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2022/1/29
Y1 - 2022/1/29
N2 - Background: Sutureless coronary anastomotic devices are intended to facilitate minimally invasive coronary artery bypass grafting (MICS-CABG) by easing and eventually standardizing the anastomotic technique. Within this systematic review and meta-analysis, we aim to determine patency and to evaluate safety outcomes for the sutureless anastomoses. Methods: CENTRAL, MED-LINE, and EMBASE were searched from database start till August 2021 in a predefined search strategy combining the key concepts: ‘coronary artery bypass grafting’, ‘sutureless coronary anastomoses’, and ‘hand-sewn coronary anastomoses’ by the Boolean operation ‘AND’. Study characteristics, patient demographics, interventional details, and all available outcome data were extracted. A meta-analysis was performed on patency at longest follow-up. Safety outcomes were presented. Results: A total of eleven trials towards six sutureless anastomotic devices were included, comprising 3724 patients (490 sutureless and 3234 hand-sewn). There was no significant difference in patency at a mean follow-up duration of 546.3 (range 1.5–2691) days, with a risk ratio of 0.77 (95% CI 0.55–1.06). MACE was reported in 4.5% sutureless and 3.9% hand-sewn patients, including all-cause mortality (resp. 1.3 vs. 1.9%), myocardial infarction (resp. 1.6 vs. 1.7%), and coronary revascularization (resp. 1.8 vs. 0.5%). Incomplete hemostasis occurred in 24.8% of the sutureless anastomoses. Intra-operative device failure forced conversion to hand-sewn or redo-anastomosis in 5.8% of the sutureless cases. Conclusion: Based on the systematic review and meta-analysis including six devices, we conclude that sutureless coronary anastomotic devices appear safe and effective when used by well-trained and dedicated surgical teams.
AB - Background: Sutureless coronary anastomotic devices are intended to facilitate minimally invasive coronary artery bypass grafting (MICS-CABG) by easing and eventually standardizing the anastomotic technique. Within this systematic review and meta-analysis, we aim to determine patency and to evaluate safety outcomes for the sutureless anastomoses. Methods: CENTRAL, MED-LINE, and EMBASE were searched from database start till August 2021 in a predefined search strategy combining the key concepts: ‘coronary artery bypass grafting’, ‘sutureless coronary anastomoses’, and ‘hand-sewn coronary anastomoses’ by the Boolean operation ‘AND’. Study characteristics, patient demographics, interventional details, and all available outcome data were extracted. A meta-analysis was performed on patency at longest follow-up. Safety outcomes were presented. Results: A total of eleven trials towards six sutureless anastomotic devices were included, comprising 3724 patients (490 sutureless and 3234 hand-sewn). There was no significant difference in patency at a mean follow-up duration of 546.3 (range 1.5–2691) days, with a risk ratio of 0.77 (95% CI 0.55–1.06). MACE was reported in 4.5% sutureless and 3.9% hand-sewn patients, including all-cause mortality (resp. 1.3 vs. 1.9%), myocardial infarction (resp. 1.6 vs. 1.7%), and coronary revascularization (resp. 1.8 vs. 0.5%). Incomplete hemostasis occurred in 24.8% of the sutureless anastomoses. Intra-operative device failure forced conversion to hand-sewn or redo-anastomosis in 5.8% of the sutureless cases. Conclusion: Based on the systematic review and meta-analysis including six devices, we conclude that sutureless coronary anastomotic devices appear safe and effective when used by well-trained and dedicated surgical teams.
KW - Anastomosis
KW - Coronary artery bypass grafting
KW - Minimally invasive
KW - Sutureless coronary anastomotic device
KW - minimally invasive
KW - sutureless coronary anastomotic device
KW - anastomosis
KW - coronary artery bypass grafting
UR - http://www.scopus.com/inward/record.url?scp=85123509884&partnerID=8YFLogxK
U2 - 10.3390/jcm11030749
DO - 10.3390/jcm11030749
M3 - Review article
C2 - 35160201
AN - SCOPUS:85123509884
SN - 2077-0383
VL - 11
SP - 1
EP - 13
JO - Journal of Clinical medicine
JF - Journal of Clinical medicine
IS - 3
M1 - 749
ER -