TY - GEN
T1 - Studying the relative impact of ghosting and noise on the perceived quality of MR images
AU - Liu, Hantao
AU - Koonen, Jos
AU - Fuderer, Miha
AU - Heynderickx, Ingrid
N1 - Publisher Copyright:
© 2012 SPIE.
PY - 2012
Y1 - 2012
N2 - In current magnetic resonance (MR) imaging systems, design choices are confronted with a trade-off between structured (i.e. artifacts) and unstructured noise. The impact of both types of noise on perceived image quality, however, is so far unknown, while this knowledge would be highly beneficial for further improvement of MR imaging systems. In this paper, we investigate how ghosting artifacts (i.e. structured noise) and random noise, applied at the same energy level in the distortion, affect the perceived quality of MR images. To this end, a perception experiment is conducted with human observers rating the quality of a set of images, distorted with various levels of ghosting and noise. To also understand the influence of professional expertise on the image quality assessment task, two groups of observers with different levels of medical imaging experience participated in the experiment: one group contained fifteen clinical scientists or application specialists, and the other group contained eighteen naïve observers. Experimental results indicate that experts and naïve observers differently assess the quality of MR images degraded with ghosting/noise. Naïve observers consistently rate images degraded with ghosting higher than images degraded with noise, independent of the energy level of the distortion, and of the image content. For experts, the relative impact of ghosting and noise on perceived quality tends to depend on the energy level of the distortion and on the image content, but overall the energy of the distortion is a promising metric to predict perceived image quality.
AB - In current magnetic resonance (MR) imaging systems, design choices are confronted with a trade-off between structured (i.e. artifacts) and unstructured noise. The impact of both types of noise on perceived image quality, however, is so far unknown, while this knowledge would be highly beneficial for further improvement of MR imaging systems. In this paper, we investigate how ghosting artifacts (i.e. structured noise) and random noise, applied at the same energy level in the distortion, affect the perceived quality of MR images. To this end, a perception experiment is conducted with human observers rating the quality of a set of images, distorted with various levels of ghosting and noise. To also understand the influence of professional expertise on the image quality assessment task, two groups of observers with different levels of medical imaging experience participated in the experiment: one group contained fifteen clinical scientists or application specialists, and the other group contained eighteen naïve observers. Experimental results indicate that experts and naïve observers differently assess the quality of MR images degraded with ghosting/noise. Naïve observers consistently rate images degraded with ghosting higher than images degraded with noise, independent of the energy level of the distortion, and of the image content. For experts, the relative impact of ghosting and noise on perceived quality tends to depend on the energy level of the distortion and on the image content, but overall the energy of the distortion is a promising metric to predict perceived image quality.
KW - Ghosting
KW - Human visual system
KW - MRI
KW - Noise
KW - Perceived image quality
UR - https://www.scopus.com/pages/publications/85027538358
U2 - 10.1117/12.911019
DO - 10.1117/12.911019
M3 - Conference contribution
AN - SCOPUS:85027538358
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2012
A2 - Abbey, Craig K.
A2 - Mello-Thoms, Claudia R.
PB - SPIE
T2 - Medical Imaging 2012: Image Perception, Observer Performance, and Technology Assessment
Y2 - 8 February 2012 through 9 February 2012
ER -