Safety and feasibility of early discharge after transcatheter aortic valve implantation with ACURATE Neo—the POLESTAR trial

Joris F. Ooms, Kristoff Cornelis, Harindra C. Wijeysundera, Bert Vandeloo, Jan Van Der Heyden, Jan Kovac, David Wood, Albert Chan, Joanna Wykyrzykowska, Liesbeth Rosseel, Michael Cunnington, Frank van der Kley, Benno Rensing, Michiel Voskuil, David Hildick-Smith, Nicolas M. Van Mieghem*

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Background: Transcatheter aortic valve implantation (TAVI) serves a growing range of patients with severe aortic stenosis (AS). TAVI has evolved to a streamlined procedure minimizing length of hospital stay. Aims: To evaluate the safety and efficacy of an early discharge (ED) strategy after TAVI. Methods: We performed an international, multi-center, prospective observational single-arm study in AS patients undergoing TAVI with the ACURATE valve platform. Eligibility for ED was assessed prior to TAVI and based on prespecified selection criteria. Discharge ≤ 48 h was defined as ED. Primary Valve Academic Research Consortium (VARC)-3-defined 30-day safety and efficacy composite endpoints were landmarked at 48 h and compared between ED and non-ED groups. Results: A total of 252 patients were included. The median age was 82 [25th–75th percentile, 78–85] years and the median Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score was 2.2% [25th–75th percentile, 1.6–3.3]. ED and non-ED were achieved in 173 (69%) and 79 (31%) patients respectively. Monitoring for conduction disturbances was the principal reason for non-ED (33%). Overall, at 30 days, all-cause mortality was 1%, new permanent pacemaker rate was 4%, and valve- or procedure-related rehospitalization was 4%. There was no difference in the primary safety and efficacy endpoint between the ED and non-ED cohorts (OR 0.84 [25th–75th percentile, 0.31–2.26], p = 0.73, and OR 0.97 [25th–75th percentile, 0.46–2.06], p = 0.94). The need for rehospitalization was similarly low for ED and non-ED groups. Conclusion: Early discharge after TAVI with the ACURATE valve is safe and feasible in selected patients. Rhythm monitoring and extended clinical observation protracted hospital stay.

Original languageEnglish
Pages (from-to)341-349
Number of pages9
JournalClinical Research in Cardiology
Volume114
Issue number3
Early online date15 Apr 2024
DOIs
Publication statusPublished - Mar 2025

Keywords

  • Early discharge
  • Self-expanding valve
  • TAVI

Fingerprint

Dive into the research topics of 'Safety and feasibility of early discharge after transcatheter aortic valve implantation with ACURATE Neo—the POLESTAR trial'. Together they form a unique fingerprint.

Cite this