Safety analysis of holmium-166 microsphere scout dose imaging during radioembolisation work-up: A cohort study

Arthur J A T Braat, Jip F Prince, Rob van Rooij, Rutger C G Bruijnen, Maurice A A J van den Bosch, Marnix G E H Lam

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

OBJECTIVE: Radioembolisation is generally preceded by a scout dose of technetium-99m-macroaggregated albumin to estimate extrahepatic shunting of activity. Holmium-166 microspheres can be used as a scout dose (±250 MBq) and as a therapeutic dose. The general toxicity of a holmium-166 scout dose ((166)Ho-SD) and safety concerns of an accidental extrahepatic deposition of (166)Ho-SD were investigated.

METHODS: All patients who received a (166)Ho-SD in our institute were reviewed for general toxicity and extrahepatic depositions. The absorbed dose in extrahepatic tissue was calculated on SPECT/CT and correlated to clinical toxicities.

RESULTS: In total, 82 patients were included. No relevant clinical toxicity occurred. Six patients had an extrahepatic deposition of (166)Ho-SD (median administered activity 270 MBq). The extrahepatic depositions (median activity 3.7 MBq) were located in the duodenum (3x), gastric fundus, falciform ligament and the lesser curvature of the stomach, and were deposited in a median volume of 15.3 ml, which resulted in an estimated median absorbed dose of 3.6 Gy (range 0.3-13.8 Gy). No adverse events related to the extrahepatic deposition of the (166)Ho-SD occurred after a median follow-up of 4 months (range 1-12 months).

CONCLUSION: These results support the safety of 250 MBq (166)Ho-SD in a clinical setting.

KEY POINTS: • A holmium-166 scout dose is safe in a clinical setting. • Holmium-166 scout dose is a safe alternative for (99m) Tc-MAA for radioembolisation work-up. • Holmium-166 scout dose potentially has several benefits over (99m) Tc-MAA for radioembolisation work-up.

Original languageEnglish
Pages (from-to)920-928
Number of pages9
JournalEuropean Radiology
Volume28
Issue number3
DOIs
Publication statusPublished - Mar 2018

Keywords

  • Embolisation
  • Holmium
  • Radioembolisation
  • SIRT
  • Technetium Tc-99m AggregatedAlbumin
  • therapeutic

Fingerprint

Dive into the research topics of 'Safety analysis of holmium-166 microsphere scout dose imaging during radioembolisation work-up: A cohort study'. Together they form a unique fingerprint.

Cite this