Skip to main navigation Skip to search Skip to main content

S2 connector versus suture: distal coronary anastomosis remodeling, patency, and function in the pig

  • Willem J.L. Suyker
  • , J.P. Matonick
  • , P.T. Suyker
  • , A. Brutel de la Rivière
  • , M.P. Buijsrogge
  • , Ricardo Budde
  • , C.W.J. Verlaan
  • , G. Pasterkamp
  • , P.F. Gründeman
  • , C. Borst

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

BACKGROUND: Anastomotic connectors could be the key to less invasive bypass surgery, including endoscopic procedures, but equivalence to conventional suturing needs to be established. A novel distal coronary connector was tested pre-clinically for safety and efficacy in comparison to conventional suturing.

METHODS AND RESULTS: Left internal thoracic to left anterior descending coronary artery bypasses were constructed off-pump in 35 pigs (73+/-8 kg). An intraluminal metal connector (S2AS) was used in 21 and conventional suturing in 14 animals. S2AS anastomosis construction was easier achieved in one-fourth of the conventional construction time (3.7+/-0.7 versus 16.5+/-2.6 minutes; P<0.001). Acute patency tended to be better (P=0.15). All anastomoses were evaluated intraoperatively, and subgroups at 90 and at 180 days. Patency was 100%. An effective remodeling response was observed in all groups, resulting in unobstructed anastomoses with excellent hemodynamic performance (fractional flow reserve > or = 0.93 at 180 days). At 6 months, the noncompliant connector was covered with stabilized neointima that was thinner than found on the suture line (0.10+/-0.04 versus 0.31+/-0.13 mm; P=0.01). The connector induced less lumen loss (-0.6+/-6.5 versus 21.6+/-19%; P=0.03). The initial side-to-side configuration had remodeled to an end-to-side shape as intended.

CONCLUSIONS: In the porcine model, the connector rapidly and consistently produced high-quality anastomoses that fully met current standards on patency and function. Unconventional aspects like a noncompliant intraluminal ring and a side-to-side to end-to-side converted configuration did not interfere with favorable anastomosis remodeling. These findings shed a new light on the anatomical prerequisites for anastomosis patency.

Original languageEnglish
Pages (from-to)I-390-I-395
Number of pages6
JournalCirculation
Volume114
Issue number1 suppl
DOIs
Publication statusPublished - 4 Jul 2006

Keywords

  • Animals
  • Coronary Angiography
  • Coronary Artery Bypass, Off-Pump
  • Corrosion Casting
  • Equipment Design
  • Female
  • Follow-Up Studies
  • Foreign-Body Reaction
  • Graft Occlusion, Vascular
  • Hemodynamics
  • Implants, Experimental
  • Internal Mammary-Coronary Artery Anastomosis
  • Postoperative Complications
  • Surgical Staplers
  • Surgical Stapling
  • Sus scrofa
  • Suture Techniques
  • Vascular Patency
  • Wound Healing