TY - JOUR
T1 - Robotic- assisted minimally invasive Ivor-Lewis handsewn anastomosis technique and outcomes from a large-volume European centre
AU - Ng, Annalisa Y L
AU - Goense, Lucas
AU - Van De Horst, Sylvia
AU - Van Den Berg, Jan Willem
AU - Ruurda, Jelle P
AU - Van Hillegersberg, Richard
N1 - Publisher Copyright:
© 2025 The Author(s). Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus.
PY - 2025/4
Y1 - 2025/4
N2 - In minimally invasive transthoracic esophagectomy, intrathoracic anastomoses are usually performed with stapling devices to avoid a technically challenging handsewn technique in the upper mediastinum. Few have published about handsewn anastomotic techniques due to the technically demanding requirements for suturing with rigid instruments in the thoracic cavity. With robot-assisted minimally invasive esophagectomy (RAMIE), the robot provides increased dexterity, enabling construction of a hand-sewn intrathoracic anastomosis. This study aimed to evaluate the outcomes of our technique for hand-sewn intrathoracic anastomosis in RAMIE, following the initial learning phase between 2016 and 2018 in UMC Utrecht. Patients who underwent RAMIE with a robot-assisted hand-sewn intrathoracic anastomosis were included in this retrospective study. Data were extracted from a prospectively maintained institutional database. Key technique steps included esophageal stay-sutures, use of barbed sutures for the anastomosis, placement of tension-releasing stitches, and covering of the anastomosis with omentum. The primary outcome was anastomotic leakage; secondary outcomes included anastomotic stricture rate and duration of anastomosis construction. Between 1 November 2019 and 30 May 2023, 89 consecutive patients were included. Anastomotic leakage (defined by the Esophageal Complications Consensus Group) occurred in 11 patients (12.4%), which involved a grade I leak in four patients (4.5%), grade II leak in one patient (1.1%), and grade III leakage in six patients (6.7%). The median duration of anastomosis creation was 33 minutes (range, 23-55 minutes). Stricture rate was 32.6% (29 patients) at 1 year post-operatively for which dilation was needed for all patients. This study shows that a robot-assisted hand-sewn intrathoracic anastomosis in RAMIE is feasible, safe, and reliable.
AB - In minimally invasive transthoracic esophagectomy, intrathoracic anastomoses are usually performed with stapling devices to avoid a technically challenging handsewn technique in the upper mediastinum. Few have published about handsewn anastomotic techniques due to the technically demanding requirements for suturing with rigid instruments in the thoracic cavity. With robot-assisted minimally invasive esophagectomy (RAMIE), the robot provides increased dexterity, enabling construction of a hand-sewn intrathoracic anastomosis. This study aimed to evaluate the outcomes of our technique for hand-sewn intrathoracic anastomosis in RAMIE, following the initial learning phase between 2016 and 2018 in UMC Utrecht. Patients who underwent RAMIE with a robot-assisted hand-sewn intrathoracic anastomosis were included in this retrospective study. Data were extracted from a prospectively maintained institutional database. Key technique steps included esophageal stay-sutures, use of barbed sutures for the anastomosis, placement of tension-releasing stitches, and covering of the anastomosis with omentum. The primary outcome was anastomotic leakage; secondary outcomes included anastomotic stricture rate and duration of anastomosis construction. Between 1 November 2019 and 30 May 2023, 89 consecutive patients were included. Anastomotic leakage (defined by the Esophageal Complications Consensus Group) occurred in 11 patients (12.4%), which involved a grade I leak in four patients (4.5%), grade II leak in one patient (1.1%), and grade III leakage in six patients (6.7%). The median duration of anastomosis creation was 33 minutes (range, 23-55 minutes). Stricture rate was 32.6% (29 patients) at 1 year post-operatively for which dilation was needed for all patients. This study shows that a robot-assisted hand-sewn intrathoracic anastomosis in RAMIE is feasible, safe, and reliable.
KW - Adult
KW - Aged
KW - Anastomosis, Surgical/methods
KW - Anastomotic Leak/etiology
KW - Esophageal Neoplasms/surgery
KW - Esophageal Stenosis/etiology
KW - Esophagectomy/methods
KW - Esophagus/surgery
KW - Female
KW - Humans
KW - Male
KW - Middle Aged
KW - Minimally Invasive Surgical Procedures/methods
KW - Retrospective Studies
KW - Robotic Surgical Procedures/methods
KW - Suture Techniques
KW - Treatment Outcome
UR - http://www.scopus.com/inward/record.url?scp=105000304425&partnerID=8YFLogxK
U2 - 10.1093/dote/doaf019
DO - 10.1093/dote/doaf019
M3 - Article
C2 - 40100150
SN - 1120-8694
VL - 38
JO - Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus
JF - Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus
IS - 2
M1 - doaf019
ER -