TY - JOUR
T1 - Quantitative videodensitometric assessment of aortic regurgitation in Myval, Sapien, and Evolut THV series
T2 - Results from the LANDMARK trial
AU - Hasabo, Elfatih A.
AU - van Royen, Niels
AU - Amat-Santos, Ignacio J.
AU - Hudec, Martin
AU - Bunc, Matjaz
AU - IJsselmuiden, Alexander
AU - Laanmets, Peep
AU - Unic, Daniel
AU - Merkely, Bela
AU - Hermanides, Renicus S.
AU - Ninios, Vlasis
AU - Protasiewicz, Marcin
AU - W M Rensing, Benno J.
AU - Martin, Pedro L.
AU - Feres, Fausto
AU - Sousa Almeida, Manuel De
AU - van Belle, Eric
AU - Linke, Axel
AU - Ielasi, Alfonso
AU - Montorfano, Matteo
AU - Webster, Mark
AU - Toutouzas, Konstantinos
AU - Teiger, Emmanuel
AU - Bedogni, Francesco
AU - Voskuil, Michiel
AU - Pan, Manuel
AU - Angerås, Oskar
AU - Kim, Won Keun
AU - Rothe, Jürgen
AU - Kristić, Ivica
AU - Peral, Vicente
AU - Van den Branden, Ben J.L.
AU - Thakkar, Ashokkumar
AU - Chandra, Udita
AU - Ayhan, Cagri
AU - Neiroukh, Dina
AU - Nosir, Mahmoud Y.
AU - Yacoub, Magdi S.
AU - Ali, Sanaa
AU - Altamimi, Mohamad
AU - Elzomor, Hesham
AU - Serruys, Patrick W.
AU - Baumbach, Andreas
AU - Soliman, Osama
N1 - Publisher Copyright:
© 2025 The Author(s)
PY - 2025/12
Y1 - 2025/12
N2 - Background: The quantitative videodensitometric aortography (QVDA) has reliably quantified post-TAVI aortic regurgitation (AR). However, this method has not yet been evaluated in randomized trials comparing various transcatheter heart valve (THV) systems. Here, we investigated the QVDA of AR following TAVI for severe aortic stenosis among Myval, Sapien, and Evolut THV series as part of the LANDMARK trial. Methods: The final aortograms, either without or after balloon post-dilatation (BPD) were analyzed using the advanced CAAS-A-Valve 2.1.2 software. The regurgitant fraction (RF) was computed and categorized into none/trace AR (RF < 86 %), mild AR (6 % ≤ 8RF ≤ 817 %), and moderate/severe AR (RF > 17 %). Results: Five hundred ninety-six final analyzable aortograms and 97 aortograms following BPD were included in the analysis. The BPD resulted in a significant reduction of RF in the Myval [12.0(6.0–18.5) vs 2.0(1.0, 5.5);p = 0.0002], Sapien[18.0(1.0–19.0) vs. 2.0(1.0–3.0); p = 0.04206] and Evolut [10.5 (6.0–15.0) vs 5.0 (1.0–8.0); p = 0.0009]. The rate of final RF > 17 % was lower in the Myval(2.0 %) compared to Evolut(8.00 %), but similar to the Sapien series (4.0 %)(PMyval-Sapien = 0.2333, PMyval-Evolut = 0.0057). In the as-treated population, the Myval series demonstrated a comparable RF to the Sapien series, but a significantly lower RF compared to the Evolut [Myval: 3.0 %(1.0–7.0), Sapien:3.0 %(1.0–7.0), Evolut:5.0 %(1.0–10.0)], PMyval-Sapien = 0.8997,PMyval-Evolut = 0.0010]. Conclusion: The QVDA highlights the superior performance of the Myval THV series compared to the Evolut THV series, with the lowest rate of moderate/severe RF among the three THV series, and could be used with echocardiography to help in detecting cases with none/trace AR.
AB - Background: The quantitative videodensitometric aortography (QVDA) has reliably quantified post-TAVI aortic regurgitation (AR). However, this method has not yet been evaluated in randomized trials comparing various transcatheter heart valve (THV) systems. Here, we investigated the QVDA of AR following TAVI for severe aortic stenosis among Myval, Sapien, and Evolut THV series as part of the LANDMARK trial. Methods: The final aortograms, either without or after balloon post-dilatation (BPD) were analyzed using the advanced CAAS-A-Valve 2.1.2 software. The regurgitant fraction (RF) was computed and categorized into none/trace AR (RF < 86 %), mild AR (6 % ≤ 8RF ≤ 817 %), and moderate/severe AR (RF > 17 %). Results: Five hundred ninety-six final analyzable aortograms and 97 aortograms following BPD were included in the analysis. The BPD resulted in a significant reduction of RF in the Myval [12.0(6.0–18.5) vs 2.0(1.0, 5.5);p = 0.0002], Sapien[18.0(1.0–19.0) vs. 2.0(1.0–3.0); p = 0.04206] and Evolut [10.5 (6.0–15.0) vs 5.0 (1.0–8.0); p = 0.0009]. The rate of final RF > 17 % was lower in the Myval(2.0 %) compared to Evolut(8.00 %), but similar to the Sapien series (4.0 %)(PMyval-Sapien = 0.2333, PMyval-Evolut = 0.0057). In the as-treated population, the Myval series demonstrated a comparable RF to the Sapien series, but a significantly lower RF compared to the Evolut [Myval: 3.0 %(1.0–7.0), Sapien:3.0 %(1.0–7.0), Evolut:5.0 %(1.0–10.0)], PMyval-Sapien = 0.8997,PMyval-Evolut = 0.0010]. Conclusion: The QVDA highlights the superior performance of the Myval THV series compared to the Evolut THV series, with the lowest rate of moderate/severe RF among the three THV series, and could be used with echocardiography to help in detecting cases with none/trace AR.
KW - Aortic regurgitation
KW - Balloon post-dilatation
KW - Regurgitant fraction
KW - Transcatheter aortic valve implantation
KW - Videodensitometry
UR - https://www.scopus.com/pages/publications/105017159241
U2 - 10.1016/j.ijcha.2025.101804
DO - 10.1016/j.ijcha.2025.101804
M3 - Article
AN - SCOPUS:105017159241
SN - 2352-9067
VL - 61
JO - IJC Heart and Vasculature
JF - IJC Heart and Vasculature
M1 - 101804
ER -