Skip to main navigation Skip to search Skip to main content

Prospective Midterm Outcomes of the PULSTA Self-Expandable Transcatheter Pulmonary Valve: The PULSTA CE Approval Study

  • Sang-Yun Lee
  • , Gi Beom Kim*
  • , Mario Carminati*
  • , Luca Giugno
  • , Ahmet Çelebi
  • , Ilker Kemal Yucel
  • , Andreas Eicken
  • , Peter Ewert
  • , Stanimir Georgiev
  • , Jae Young Choi
  • , Chang Sin Kim
  • , Federico Gutiérrez-Larraya
  • , Enrique Balbacid Domingo
  • , Ender Odemis
  • , Mete Han Kizilkaya
  • , José Luis Zunzunegui
  • , Fernando Ballesteros Tejerizo
  • , Seong-Ho Kim
  • , So-Ick Jang
  • , Thomas Krasemann
  • Gregor Krings
*Corresponding author for this work

Research output: Contribution to journal › Article › Academic › peer-review

Abstract

BACKGROUND: – Patients with congenital or acquired right ventricular outflow tract dysfunction frequently require pulmonary valve replacement and are exposed to repeated surgical interventions due to prosthetic valve degeneration. The PULSTA self-expanding transcatheter pulmonary valve was designed to address a broad spectrum of native and surgically repaired right ventricular outflow tract anatomies. This study reports the midterm safety, hemodynamic performance, and durability outcomes of the prospective, multinational PULSTA CE approval trial (PULSTA Carpentier Edwards). METHODS: – This premarket, multicenter, nonrandomized study enrolled 58 patients across 11 centers in 6 countries. Successful PULSTA implantation was achieved in 57 patients (98.3%), including 4 valve-in-valve procedures. Patients were followed for a median duration of 4.1 years. Primary end points included procedural or device-related serious adverse events, hemodynamic improvement, and sustained valve function. RESULTS: – At 6 months, cardiac magnetic resonance imaging demonstrated significant reverse right ventricular remodeling, with marked reductions in right ventricular end-diastolic volume index, end-systolic volume index, and pulmonary regurgitation fraction (all P<0.001). Valve performance remained stable throughout follow-up, with 93.8% of patients exhibiting mild or less pulmonary regurgitation at 4.1 years. Freedom from reintervention was 98.2% at 5 years. One patient required a PULSTA-in-PULSTA implantation due to paravalvular leakage, and one case of infective endocarditis was successfully managed with antibiotic therapy. No stent fractures or structural valve deterioration were observed. CONCLUSIONS: – The PULSTA transcatheter pulmonary valve demonstrated high procedural success, durable valve function, and sustained hemodynamic benefits. Its adaptability to diverse right ventricular outflow tract anatomies and favorable safety profile supports its role as an effective therapeutic option for patients with right ventricular outflow tract dysfunction. REGISTRATION: – URL: https://www.clinicaltrials.gov; Unique identifier: NCT03983512.

Original languageEnglish
Article numbere016616
JournalCirculation. Cardiovascular Interventions
Volume19
Early online date18 Jun 2026
DOIs
Publication statusPublished - Sept 2026

Keywords

  • catheters
  • endocarditis
  • follow-up studies
  • pulmonary valve
  • pulmonary valve insufficiency

Fingerprint

Dive into the research topics of 'Prospective Midterm Outcomes of the PULSTA Self-Expandable Transcatheter Pulmonary Valve: The PULSTA CE Approval Study'. Together they form a unique fingerprint.

Cite this