Preliminary intraobserver and interobserver variability in wall stress and rupture risk assessment of abdominal aortic aneurysms using a semiautomatic finite element model.

Translated title of the contribution: Preliminary intraobserver and interobserver variability in wall stress and rupture risk assessment of abdominal aortic aneurysms using a semiautomatic finite element model.

A. Teutelink, E. Cancrinus, D. van de Heuvel, F.L. Moll, J.P.P.M. de Vries

Research output: Contribution to journalArticleAcademicpeer-review

Translated title of the contributionPreliminary intraobserver and interobserver variability in wall stress and rupture risk assessment of abdominal aortic aneurysms using a semiautomatic finite element model.
Original languageUndefined/Unknown
Pages (from-to)326-330
Number of pages5
JournalJournal of Vascular Surgery
Volume55
Issue number2
Publication statusPublished - 2012