Phosphorylcholine coating of bypass systems used for young infants does not attenuate the inflammatory response

Anjo M. Draaisma*, Mark G. Hazekamp, Nanning Anes, Paul Schoof, C. Erik Hack, Augueste Sturk, Robert A.E. Dion

*Corresponding author for this work

    Research output: Contribution to journalArticleAcademicpeer-review

    12 Citations (Scopus)

    Abstract

    Background. Contact of blood with the artificial surfaces of the cardiopulmonary bypass (CPB) system is considered to be a main cause of complement activation. Improving the biocompatibility of the system by reduction of contact activation of blood elements and thereby producing less inflammatory response is evidently desired, especially for neonates and infants who are more susceptible to the deleterious effects of CPB. A phosphorylcholine coating, Phisio, is designed to mimic the natural interfaces of blood. The aim of this study is to compare the influence of a phosphorylcholine-coated CPB system versus an uncoated CPB system on complement activation and clinical outcomes. Methods. In this prospective, randomized, blind, one-center study, 28 neonates and infants with a bodyweight between 3 and 6 kg who were undergoing cardiopulmonary bypass were divided in two groups, the phosphorylcholine group and the control group. Thirteen patients were assigned to the phosphorylcholine group and 15 patients to the control group. Patients with Down syndrome, prematurity, cyanosis, or reoperation were excluded. Complement factor C3b/c, human neutrophil elastase (HNE), interleukin-6, and C-reactive protein were measured before, during, and after CPB. Duration of intensive care stay, ventilation time, highest body temperature, and inotropic medication were the clinical variables. Results. No significant differences were found between the groups for complement factor C3b/c, HNE, interleukin-6, or C-reactive protein during and after CPB. No clinical differences were observed between the groups. Conclusions. Phosphorylcholine coating does not attenuate the complement activation during CPB in neonates and infants.

    Original languageEnglish
    Pages (from-to)1455-1459
    Number of pages5
    JournalAnnals of Thoracic Surgery
    Volume81
    Issue number4
    DOIs
    Publication statusPublished - Apr 2006

    Fingerprint

    Dive into the research topics of 'Phosphorylcholine coating of bypass systems used for young infants does not attenuate the inflammatory response'. Together they form a unique fingerprint.

    Cite this