TY - JOUR
T1 - Percutaneous atrial shunt closure using the novel occlutech figulla device
T2 - 6-month efficacy and safety
AU - Van Den Branden, Ben J L
AU - Post, Martijn C.
AU - Plokker, Herbert W M
AU - Ten Berg, Jurriën M.
AU - Suttorp, Maarten J.
PY - 2011/6/1
Y1 - 2011/6/1
N2 - Background: The Occlutech Figulla Occluder is a new innovative device for percutaneous closure of a patent foramen ovale (PFO) and an atrial septum defect (ASD). We describe the safety and efficacy of this new device at 6-month follow-up. Methods: All 82 consecutive patients (51% female, mean age 49.0 ± 13.6 years) who underwent percutaneous PFO (n = 48) or ASD (n = 34) closure between October 2008 and October 2009 were included. Results: Implantation success was 100%. The in-hospital complications were two new onset supraventricular tachycardia (SVT) (2.4%, both ASD patients), nine minimal groin hematoma's (11.0%, 4 PFO and 5 ASD patients), and one transient ST elevation during the procedure (1.2%, ASD patient). During 6 months follow-up (n = 79), no major complications or reoccurrences of cerebral thrombo-embolic events did occur. Seven patients (8.9%, 6 PFO and 1 ASD patient) experienced a new SVT. One patient developed a recurrent cerebral hemorrhage 5 months after ASD closure, which appeared not to be related to the procedure. Using contrast transthoracic echocardiography 6 months after PFO closure (n = 45), a residual shunt was present in 30.2% of the patients (small 25.6%, moderate 4.6%, severe 0%). In the ASD group (n = 34), a residual shunt was observed in 32.5% (small 17.7%, moderate 14.7%, severe 2.9%). Conclusion: The Occlutech Figulla Occluder appears to be easy to use, effective, and safe for percutaneous closure of PFO and ASD. We report a low complication rate but a relative high percentage of small residual shunts 6 months after closure.
AB - Background: The Occlutech Figulla Occluder is a new innovative device for percutaneous closure of a patent foramen ovale (PFO) and an atrial septum defect (ASD). We describe the safety and efficacy of this new device at 6-month follow-up. Methods: All 82 consecutive patients (51% female, mean age 49.0 ± 13.6 years) who underwent percutaneous PFO (n = 48) or ASD (n = 34) closure between October 2008 and October 2009 were included. Results: Implantation success was 100%. The in-hospital complications were two new onset supraventricular tachycardia (SVT) (2.4%, both ASD patients), nine minimal groin hematoma's (11.0%, 4 PFO and 5 ASD patients), and one transient ST elevation during the procedure (1.2%, ASD patient). During 6 months follow-up (n = 79), no major complications or reoccurrences of cerebral thrombo-embolic events did occur. Seven patients (8.9%, 6 PFO and 1 ASD patient) experienced a new SVT. One patient developed a recurrent cerebral hemorrhage 5 months after ASD closure, which appeared not to be related to the procedure. Using contrast transthoracic echocardiography 6 months after PFO closure (n = 45), a residual shunt was present in 30.2% of the patients (small 25.6%, moderate 4.6%, severe 0%). In the ASD group (n = 34), a residual shunt was observed in 32.5% (small 17.7%, moderate 14.7%, severe 2.9%). Conclusion: The Occlutech Figulla Occluder appears to be easy to use, effective, and safe for percutaneous closure of PFO and ASD. We report a low complication rate but a relative high percentage of small residual shunts 6 months after closure.
UR - https://www.scopus.com/pages/publications/79959835416
U2 - 10.1111/j.1540-8183.2010.00619.x
DO - 10.1111/j.1540-8183.2010.00619.x
M3 - Article
C2 - 21198853
AN - SCOPUS:79959835416
SN - 0896-4327
VL - 24
SP - 264
EP - 270
JO - Journal of Interventional Cardiology
JF - Journal of Interventional Cardiology
IS - 3
ER -