N2 - Institution of extracorporeal membrane oxygenation (ECMO) results in unique blood flow characteristics to the end-organ vascular beds. We studied the interplay between cardiac-driven and extracorporeal membrane oxygenation (ECMO)-driven flow to vascular beds in different ECMO configurations using a patient-specific computational fluid dynamics (CFD) analysis. A computational ECMO model (femoral artery cannulation [FAC]) was constructed using patient-specific imaging and hemodynamic data. Following model calibration, we augmented the 3D geometrical model to represent alternative ECMO configurations (ascending aorta cannulation [AAC] and subclavian artery cannulation [SAC]). We performed CFD analyses, including a novel virtual color-dye analysis to compare global and regional blood flow and pressure characteristics as well as contributions of cardiac and ECMO-derived flow to the various vascular beds. Flow waveforms at all the aortic branch vessels were pulsatile, despite low cardiac output and predominant nonpulsatile ECMO-driven hemodynamics. Virtual color-dye analysis revealed differential contribution of cardiac and ECMO-derived flow to the end-organ vascular beds in the FAC model, while this was more evenly distributed in the AAC and SAC models. While global hemodynamics were relatively similar between various ECMO configurations, several distinct hemodynamic indices, in particular wall shear stress and oscillatory shear patterns, as well as differential contribution of ECMO-derived flow to various vascular beds, showed remarkable differences. The clinical impact of this study highlighting the relevance of CFD modeling in assessment of complex hemodynamics in ECMO warrants further evaluation.
AB - Institution of extracorporeal membrane oxygenation (ECMO) results in unique blood flow characteristics to the end-organ vascular beds. We studied the interplay between cardiac-driven and extracorporeal membrane oxygenation (ECMO)-driven flow to vascular beds in different ECMO configurations using a patient-specific computational fluid dynamics (CFD) analysis. A computational ECMO model (femoral artery cannulation [FAC]) was constructed using patient-specific imaging and hemodynamic data. Following model calibration, we augmented the 3D geometrical model to represent alternative ECMO configurations (ascending aorta cannulation [AAC] and subclavian artery cannulation [SAC]). We performed CFD analyses, including a novel virtual color-dye analysis to compare global and regional blood flow and pressure characteristics as well as contributions of cardiac and ECMO-derived flow to the various vascular beds. Flow waveforms at all the aortic branch vessels were pulsatile, despite low cardiac output and predominant nonpulsatile ECMO-driven hemodynamics. Virtual color-dye analysis revealed differential contribution of cardiac and ECMO-derived flow to the end-organ vascular beds in the FAC model, while this was more evenly distributed in the AAC and SAC models. While global hemodynamics were relatively similar between various ECMO configurations, several distinct hemodynamic indices, in particular wall shear stress and oscillatory shear patterns, as well as differential contribution of ECMO-derived flow to various vascular beds, showed remarkable differences. The clinical impact of this study highlighting the relevance of CFD modeling in assessment of complex hemodynamics in ECMO warrants further evaluation.
KW - computational fluid dynamics
KW - extracorporeal membrane oxygenation
KW - patient-specific modeling
KW - virtual color-dye analysis