TY - JOUR
T1 - Orthotopic branched endovascular aortic arch repair in patients who cannot undergo classical surgery
AU - Czerny, Martin
AU - Rylski, Bartosz
AU - Morlock, Julia
AU - Schröfel, Holger
AU - Beyersdorf, Friedhelm
AU - Lebes, Bertrand Saint
AU - Meyrignac, Olivier
AU - Mokrane, Fatima
AU - Lescan, Mario
AU - Schlensak, Christian
AU - Hazenberg, Constatijn
AU - Bloemert-Tuin, Trijntje
AU - Braithwaite, Sue
AU - van Herwaarden, Joost
AU - Rousseau, Herve
N1 - Publisher Copyright:
© The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
PY - 2018/5/1
Y1 - 2018/5/1
N2 - OBJECTIVES: Our goal was to assess the results after orthotopic branched endovascular aortic arch repair using a new double-branch endoprosthesis in patients with thoracic aortic disease affecting the aortic arch who cannot undergo classical surgery. METHODS: Within a 4-year period, 15 patients with thoracic aortic disease affecting the aortic arch were treated with the Bolton Relay plus double-branch endoprosthesis (Bolton Medical, Sunrise, FL, USA). We assessed clinical outcome, occurrence of endoleaks and the need for secondary interventions. The median logistic EuroSCORE I level was 13.6 (4.2; 22.8). RESULTS: The in-hospital mortality rate was 6.7%. A disabling stroke was observed in 1 (6.7%) patient, whereas non-disabling strokes occurred in 2 (13.3%) patients. Type I and III endoleaks occurred in 6.7%. The median follow-up period was 263 (1st quartile 84; 2nd quartile 564) days. Four patients died during the follow-up period. Aortic-related survival was 100%. CONCLUSIONS: Orthotopic branched endovascular aortic arch repair using the Bolton Relay Plus double-branch endoprosthesis is a safe and feasible technique enriching the armamentarium to treat patients with thoracic aortic disease who cannot undergo classical surgery. Aortic-related survival is excellent, and the occurrence of disabling stroke and endoleaks warranting treatment is low. Further studies are needed to assess the long-term durability of this new method.
AB - OBJECTIVES: Our goal was to assess the results after orthotopic branched endovascular aortic arch repair using a new double-branch endoprosthesis in patients with thoracic aortic disease affecting the aortic arch who cannot undergo classical surgery. METHODS: Within a 4-year period, 15 patients with thoracic aortic disease affecting the aortic arch were treated with the Bolton Relay plus double-branch endoprosthesis (Bolton Medical, Sunrise, FL, USA). We assessed clinical outcome, occurrence of endoleaks and the need for secondary interventions. The median logistic EuroSCORE I level was 13.6 (4.2; 22.8). RESULTS: The in-hospital mortality rate was 6.7%. A disabling stroke was observed in 1 (6.7%) patient, whereas non-disabling strokes occurred in 2 (13.3%) patients. Type I and III endoleaks occurred in 6.7%. The median follow-up period was 263 (1st quartile 84; 2nd quartile 564) days. Four patients died during the follow-up period. Aortic-related survival was 100%. CONCLUSIONS: Orthotopic branched endovascular aortic arch repair using the Bolton Relay Plus double-branch endoprosthesis is a safe and feasible technique enriching the armamentarium to treat patients with thoracic aortic disease who cannot undergo classical surgery. Aortic-related survival is excellent, and the occurrence of disabling stroke and endoleaks warranting treatment is low. Further studies are needed to assess the long-term durability of this new method.
KW - Aortic arch
KW - Branched endovascular aortic repair
KW - Thoracic endovascular aortic repair
UR - http://www.scopus.com/inward/record.url?scp=85047020478&partnerID=8YFLogxK
U2 - 10.1093/ejcts/ezx493
DO - 10.1093/ejcts/ezx493
M3 - Article
C2 - 29351610
AN - SCOPUS:85047020478
SN - 1010-7940
VL - 53
SP - 1007
EP - 1012
JO - European Journal of Cardio-thoracic Surgery
JF - European Journal of Cardio-thoracic Surgery
IS - 5
ER -