TY - JOUR
T1 - Normal imaging findings after aortic valve implantation on
18F-Fluorodeoxyglucose positron emission tomography with computed tomography
AU - Wahadat, Ali R
AU - Tanis, Wilco
AU - Scholtens, Asbjørn M
AU - Bekker, Margreet
AU - Graven, Laura H
AU - Swart, Laurens E
AU - den Harder, Annemarie M
AU - Lam, Marnix G E H
AU - de Heer, Linda M
AU - Roos-Hesselink, Jolien W
AU - Budde, Ricardo P J
N1 - Funding Information:
The study was partially funded by a Grant of the Dutch Heart Foundation (NHF 2013T071) and Stichting Coolsingel (Project 527).
Publisher Copyright:
© 2020, The Author(s).
PY - 2021/10
Y1 - 2021/10
N2 - BACKGROUND: To determine the normal perivalvular 18F-Fluorodeoxyglucose (18F-FDG) uptake on positron emission tomography (PET) with computed tomography (CT) within one year after aortic prosthetic heart valve (PHV) implantation.METHODS: Patients with uncomplicated aortic PHV implantation were prospectively included and underwent 18F-FDG PET/CT at either 5 (± 1) weeks (group 1), 12 (± 2) weeks (group 2) or 52 (± 8) weeks (group 3) after implantation. 18F-FDG uptake around the PHV was scored qualitatively (none/low/intermediate/high) and quantitatively by measuring the maximum Standardized Uptake Value (SUVmax) and target to background ratio (SUVratio).RESULTS: In total, 37 patients (group 1: n = 12, group 2: n = 12, group 3: n = 13) (mean age 66 ± 8 years) were prospectively included. Perivalvular 18F-FDG uptake was low (8/12 (67%)) and intermediate (4/12 (33%)) in group 1, low (7/12 (58%)) and intermediate (5/12 (42%)) in group 2, and low (8/13 (62%)) and intermediate (5/13 (38%)) in group 3 (P = 0.91). SUVmax was 4.1 ± 0.7, 4.6 ± 0.9 and 3.8 ± 0.7 (mean ± SD, P = 0.08), and SUVratio was 2.0 [1.9 to 2.2], 2.0 [1.8 to 2.6], and 1.9 [1.7 to 2.0] (median [IQR], P = 0.81) for groups 1, 2, and 3, respectively.CONCLUSION: Non-infected aortic PHV have similar low to intermediate perivalvular 18F-FDG uptake with similar SUVmax and SUVratio at 5, 12, and 52 weeks after implantation.
AB - BACKGROUND: To determine the normal perivalvular 18F-Fluorodeoxyglucose (18F-FDG) uptake on positron emission tomography (PET) with computed tomography (CT) within one year after aortic prosthetic heart valve (PHV) implantation.METHODS: Patients with uncomplicated aortic PHV implantation were prospectively included and underwent 18F-FDG PET/CT at either 5 (± 1) weeks (group 1), 12 (± 2) weeks (group 2) or 52 (± 8) weeks (group 3) after implantation. 18F-FDG uptake around the PHV was scored qualitatively (none/low/intermediate/high) and quantitatively by measuring the maximum Standardized Uptake Value (SUVmax) and target to background ratio (SUVratio).RESULTS: In total, 37 patients (group 1: n = 12, group 2: n = 12, group 3: n = 13) (mean age 66 ± 8 years) were prospectively included. Perivalvular 18F-FDG uptake was low (8/12 (67%)) and intermediate (4/12 (33%)) in group 1, low (7/12 (58%)) and intermediate (5/12 (42%)) in group 2, and low (8/13 (62%)) and intermediate (5/13 (38%)) in group 3 (P = 0.91). SUVmax was 4.1 ± 0.7, 4.6 ± 0.9 and 3.8 ± 0.7 (mean ± SD, P = 0.08), and SUVratio was 2.0 [1.9 to 2.2], 2.0 [1.8 to 2.6], and 1.9 [1.7 to 2.0] (median [IQR], P = 0.81) for groups 1, 2, and 3, respectively.CONCLUSION: Non-infected aortic PHV have similar low to intermediate perivalvular 18F-FDG uptake with similar SUVmax and SUVratio at 5, 12, and 52 weeks after implantation.
KW - Image interpretation
KW - Infection
KW - Inflammation
KW - PET
KW - Valvular heart disease
UR - http://www.scopus.com/inward/record.url?scp=85078088962&partnerID=8YFLogxK
U2 - 10.1007/s12350-019-02025-y
DO - 10.1007/s12350-019-02025-y
M3 - Article
C2 - 31975327
SN - 1071-3581
VL - 28
SP - 2258
EP - 2268
JO - Journal of Nuclear Cardiology
JF - Journal of Nuclear Cardiology
IS - 5
ER -