Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

Wilco Tanis*, Dominika Suchá, Ward Laufer, Jesse Habets, Lex A. van Herwerden, Petr Symersky, Steven Chamuleau, Ricardo P J Budde

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Objectives: Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). Methods: PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Results: Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. Conclusion: MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. Key Points: • Retrospective MDCT is increasingly used for prosthetic heart valve dysfunction assessment • In case of PHV reoperation, invasive coronary angiography is also required • MDCT can replace CAG in 50 % of patients without coronary artery disease • When conclusive for coronary assessment, MDCT stenosis rule out is highly accurate • Replacing CAG saves associated risks of distant embolization of thrombi or vegetations

Original languageEnglish
Pages (from-to)1623-1630
Number of pages8
JournalEuropean Radiology
Volume25
Issue number6
DOIs
Publication statusPublished - 1 Jun 2015

Keywords

  • Coronary artery bypass grafts
  • Coronary artery stenosis
  • Invasive coronary angiography
  • Multidetector-row computed tomography
  • Prosthetic heart valve