Skip to main navigation Skip to search Skip to main content

Microhook Nerve Connector Cable Grafting: A Cadaveric Study of Biomechanical Integrity

  • M. D. Mazur*
  • , S. S. Dalton
  • , G. Bendale
  • , J. Isaacs
  • *Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Purpose Cable grafting is a well-established technique for repairing major peripheral nerve defects but requires extensive microsurgical suturing, increasing operative time and foreign body burden at the coaptation. A novel microhook nerve connector (MNC), originally developed to improve surgical efficiency and repair alignment in direct coaptations, could offer a potential alternative to microsuture cable grafting. This study evaluated the biomechanical integrity of MNC cable grafting compared to traditional microsutures in a cadaver model. Our hypothesis is that cable-graft repairs using MNC will demonstrate greater holding strength than those repaired with microsutures. Methods After transection, 16 cadaveric nerves (5–6 mm diameter) were reconstructed through cable grafting with either an MNC or microsutures. Sixty-four smaller nerves (1.5–2 mm diameter) were cut to 3 cm length and assembled into 4-strand cable grafts. In the microsuture group, each strand was inset on both ends with two 9-0 nylon sutures. In the MNC group, each strand was positioned onto a single microhook column, secured, and wrapped in the small intestinal submucosa backing. Biomechanical integrity was assessed via tensile testing to determine load to failure. Results MNC-assisted repairs exhibited significantly higher maximum load to failure than microsuture repairs (3.05 ± 0.57 N vs 1.55 ± 0.53 N). Both groups demonstrated sequential failure patterns, with MNC repairs sustaining significantly higher loads at each failure peak. Observationally, nerve strands from MNC repairs remained entubulated during sequential failure, temporarily maintaining the proximity of nerve ends. Conclusions MNC cable grafts demonstrated higher biomechanical holding strength overall and of each individual strand. Clinical Relevance The MNC is a sutureless alternative to traditional microsuture cable grafting. These findings support further investigation of MNC-assisted cable grafting for clinical use in major peripheral nerve repairs.

Original languageEnglish
Pages (from-to)406.e1-406.e6
JournalJournal of Hand Surgery
Volume51
Issue number4
Early online date29 Jan 2026
DOIs
Publication statusPublished - Apr 2026

Keywords

  • Biomechanics
  • cable graft
  • cadaver
  • nerve
  • nerve tape

Fingerprint

Dive into the research topics of 'Microhook Nerve Connector Cable Grafting: A Cadaveric Study of Biomechanical Integrity'. Together they form a unique fingerprint.

Cite this