TY - JOUR
T1 - Medium-term systemic blood pressure after stenting of aortic coarctation
T2 - A systematic review and meta-analysis
AU - Meijs, Timion A
AU - Warmerdam, Evangeline G
AU - Slieker, Martijn G
AU - Krings, Gregor J
AU - Molenschot, Mirella M C
AU - Meijboom, Folkert J
AU - Sieswerda, Gertjan T
AU - Doevendans, Pieter A
AU - Bouma, Berto J
AU - de Winter, Robbert J
AU - Mulder, Barbara J M
AU - Voskuil, Michiel
N1 - © Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.
PY - 2019/10/1
Y1 - 2019/10/1
N2 - Objective Long-term prognosis of patients with coarctation of the aorta (CoA) is impaired due to the high prevalence of hypertension and consequent cardiovascular complications. Although stent implantation results in acute anatomical and haemodynamic benefit, limited evidence exists regarding the late clinical outcome. In this meta-analysis, we aimed to evaluate the medium-term effect of stent placement for CoA on systemic blood pressure (BP). Methods PubMed, EMBASE and Cochrane databases were searched for non-randomised cohort studies addressing systemic BP ≥12 months following CoA stenting. Meta-analysis was performed on the change in BP from baseline to last follow-up using a random-effects model. Subgroup analyses and meta-regression were conducted to identify sources of heterogeneity between studies. Results Twenty-six studies with a total of 1157 patients and a median follow-up of 26 months were included for final analysis. Meta-analysis showed a 20.3 mm Hg (95% CI 16.4 to 24.1 mm Hg; p<0.00001) reduction in systolic BP and an 8.2 mm Hg (12 studies; 95% CI 5.2 to 11.3 mm Hg; p<0.00001) reduction in diastolic BP. A concomitant decrease in the use of antihypertensive medication was observed. High systolic BP and peak systolic gradient at baseline and stenting of native CoA were associated with a greater reduction in systolic BP at follow-up. Conclusions Stent implantation for CoA is associated with a significant decline in systolic and diastolic BP during medium-term follow-up. The degree of BP reduction appears to be dependent on baseline systolic BP, baseline peak systolic gradient, and whether stenting is performed for native or recurrent CoA.
AB - Objective Long-term prognosis of patients with coarctation of the aorta (CoA) is impaired due to the high prevalence of hypertension and consequent cardiovascular complications. Although stent implantation results in acute anatomical and haemodynamic benefit, limited evidence exists regarding the late clinical outcome. In this meta-analysis, we aimed to evaluate the medium-term effect of stent placement for CoA on systemic blood pressure (BP). Methods PubMed, EMBASE and Cochrane databases were searched for non-randomised cohort studies addressing systemic BP ≥12 months following CoA stenting. Meta-analysis was performed on the change in BP from baseline to last follow-up using a random-effects model. Subgroup analyses and meta-regression were conducted to identify sources of heterogeneity between studies. Results Twenty-six studies with a total of 1157 patients and a median follow-up of 26 months were included for final analysis. Meta-analysis showed a 20.3 mm Hg (95% CI 16.4 to 24.1 mm Hg; p<0.00001) reduction in systolic BP and an 8.2 mm Hg (12 studies; 95% CI 5.2 to 11.3 mm Hg; p<0.00001) reduction in diastolic BP. A concomitant decrease in the use of antihypertensive medication was observed. High systolic BP and peak systolic gradient at baseline and stenting of native CoA were associated with a greater reduction in systolic BP at follow-up. Conclusions Stent implantation for CoA is associated with a significant decline in systolic and diastolic BP during medium-term follow-up. The degree of BP reduction appears to be dependent on baseline systolic BP, baseline peak systolic gradient, and whether stenting is performed for native or recurrent CoA.
KW - aortic coarctation
KW - endovascular procedures for aortic and vascular disease
KW - hypertension
KW - meta-analysis
UR - https://www.scopus.com/pages/publications/85072151800
U2 - 10.1136/heartjnl-2019-314965
DO - 10.1136/heartjnl-2019-314965
M3 - Article
C2 - 31315937
SN - 1355-6037
VL - 105
SP - 1464
EP - 1470
JO - Heart
JF - Heart
IS - 19
ER -