T1 - Ion suppression, reduced long-term robustness and leakage current of the spray voltage during the ionization of trichloroacetic acid; a case study with a methylmalonic acid assay
AU - Punt, Arjen M.
AU - van der Elst, Kim C.M.
AU - Huitema, Alwin D.R.
AU - Lentjes, Eef G.W.M.
N1 - Publisher Copyright:
© 2023 The Author(s)
PY - 2023/5/30
Y1 - 2023/5/30
N2 - Sample clean-up with the protein precipitation solvent trichloroacetic acid (TCA), combined with a stable isotope labeled internal standard, is widely used for the analysis of endogenous and exogenous compounds in serum and plasma with liquid chromatography-tandem mass spectrometry (LC–MS/MS). During the application of an assay for methylmalonic acid (MMA), used for routine analysis in patient care, negative long-term side effects of TCA on assay performance were observed. Step-by-step extensive troubleshooting disclosed the limitations of using TCA in MS. After running over 2000 samples with the MMA assay over a course of one year, a black coating formed between the probe and the heater that was traced to the use of TCA. The MMA assay used a C18 column with an isocratic eluent of 95% water (0.1% formic acid) as starting condition, on which TCA was more retained than MMA. Next, concentrations of 2.2% TCA in the prepared serum or plasma sample caused a drop in spray voltage during ionization into the MS. This was caused by the strong acid properties of TCA, resulting in current loss of the spray voltage between the heated electrospray ionization (HESI) needle and the union holder, which had also a grounding function. Replacing the original metal HESI needle with a custom made fussed silica HESI needle or detaching the union from the union holder, eliminated the effect of the drop in spray voltage. In conclusion, TCA can seriously affect the long-term robustness by affecting the source of the MS. We recommend the use of a very low sample injection volume, and/or shifting the mobile phase to waste when TCA is eluting, when using TCA in LC-MS/MS analysis.
AB - Sample clean-up with the protein precipitation solvent trichloroacetic acid (TCA), combined with a stable isotope labeled internal standard, is widely used for the analysis of endogenous and exogenous compounds in serum and plasma with liquid chromatography-tandem mass spectrometry (LC–MS/MS). During the application of an assay for methylmalonic acid (MMA), used for routine analysis in patient care, negative long-term side effects of TCA on assay performance were observed. Step-by-step extensive troubleshooting disclosed the limitations of using TCA in MS. After running over 2000 samples with the MMA assay over a course of one year, a black coating formed between the probe and the heater that was traced to the use of TCA. The MMA assay used a C18 column with an isocratic eluent of 95% water (0.1% formic acid) as starting condition, on which TCA was more retained than MMA. Next, concentrations of 2.2% TCA in the prepared serum or plasma sample caused a drop in spray voltage during ionization into the MS. This was caused by the strong acid properties of TCA, resulting in current loss of the spray voltage between the heated electrospray ionization (HESI) needle and the union holder, which had also a grounding function. Replacing the original metal HESI needle with a custom made fussed silica HESI needle or detaching the union from the union holder, eliminated the effect of the drop in spray voltage. In conclusion, TCA can seriously affect the long-term robustness by affecting the source of the MS. We recommend the use of a very low sample injection volume, and/or shifting the mobile phase to waste when TCA is eluting, when using TCA in LC-MS/MS analysis.
KW - Ionsuppression
KW - LC-MS/MS
KW - Methylmalonic acid
KW - Protein precipitation
KW - Trichloroacetic acid
UR - http://www.scopus.com/inward/record.url?scp=85159272215&partnerID=8YFLogxK
U2 - 10.1016/j.jchromb.2023.123727
DO - 10.1016/j.jchromb.2023.123727
M3 - Article
AN - SCOPUS:85159272215
SN - 1570-0232
VL - 1224
JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
M1 - 123727
ER -