TY - JOUR
T1 - Individual Lesion-Level Meta-Analysis Comparing Various Doses of Intracoronary Bolus Injection of Adenosine With Intravenous Administration of Adenosine for Fractional Flow Reserve Assessment
AU - Wijntjens, Gilbert W M
AU - van Uffelen, Ellen L
AU - Echavarría-Pinto, Mauro
AU - Casadonte, Lorena
AU - Stegehuis, Valérie E
AU - Murai, Tadashi
AU - Marques, Koen M J
AU - Yoon, Myeong-Ho
AU - Tahk, Seung-Jea
AU - Casella, Gianni
AU - Leone, Antonio M
AU - López Palop, Ramón
AU - Schlundt, Christian
AU - Rivero, Fernando
AU - Petraco, Ricardo
AU - Fearon, William F
AU - Johnson, Nils P
AU - Jeremias, Allen
AU - Koo, Bon-Kwon
AU - Piek, Jan J
AU - van de Hoef, Tim P
N1 - Publisher Copyright:
© 2019 American Heart Association, Inc.
PY - 2020/1
Y1 - 2020/1
N2 - Background: Intravenous infusion of adenosine is considered standard practice for fractional flow reserve (FFR) assessment but is associated with adverse side-effects and is time-consuming. Intracoronary bolus injection of adenosine is better tolerated by patients, cheaper, and less time-consuming. However, current literature remains fragmented and modestly sized regarding the equivalence of intracoronary versus intravenous adenosine. We aim to investigate the relationship between intracoronary adenosine and intravenous adenosine to determine FFR. Methods: We performed a lesion-level meta-analysis to compare intracoronary adenosine with intravenous adenosine (140 µg/kg per minute) for FFR assessment. The search was conducted in accordance to the Preferred Reporting for Systematic Reviews and Meta-Analysis statement. Lesion-level data were obtained by contacting the respective authors or by digitization of scatterplots using custom-made software. Intracoronary adenosine dose was defined as; low: <40 µg, intermediate: 40 to 99 µg, and high: ≥100 µg. Results: We collected 1972 FFR measurements (1413 lesions) comparing intracoronary with intravenous adenosine from 16 studies. There was a strong correlation (correlation coefficient =0.915; P<0.001) between intracoronary-FFR and intravenous-FFR. Mean FFR was 0.81±0.11 for intracoronary adenosine and 0.81±0.11 for intravenous adenosine (P<0.001). We documented a nonclinically relevant mean difference of 0.006 (limits of agreement: -0.066 to 0.078) between the methods. When stratified by the intracoronary adenosine dose, mean differences between intracoronary and intravenous-FFR amounted to 0.004, 0.011, or 0.000 FFR units for low-dose, intermediate-dose, and high-dose intracoronary adenosine, respectively. Conclusions: The present study documents clinically irrelevant differences in FFR values obtained with intracoronary versus intravenous adenosine. Intracoronary adenosine hence confers a practical and patient-friendly alternative for intravenous adenosine for FFR assessment.
AB - Background: Intravenous infusion of adenosine is considered standard practice for fractional flow reserve (FFR) assessment but is associated with adverse side-effects and is time-consuming. Intracoronary bolus injection of adenosine is better tolerated by patients, cheaper, and less time-consuming. However, current literature remains fragmented and modestly sized regarding the equivalence of intracoronary versus intravenous adenosine. We aim to investigate the relationship between intracoronary adenosine and intravenous adenosine to determine FFR. Methods: We performed a lesion-level meta-analysis to compare intracoronary adenosine with intravenous adenosine (140 µg/kg per minute) for FFR assessment. The search was conducted in accordance to the Preferred Reporting for Systematic Reviews and Meta-Analysis statement. Lesion-level data were obtained by contacting the respective authors or by digitization of scatterplots using custom-made software. Intracoronary adenosine dose was defined as; low: <40 µg, intermediate: 40 to 99 µg, and high: ≥100 µg. Results: We collected 1972 FFR measurements (1413 lesions) comparing intracoronary with intravenous adenosine from 16 studies. There was a strong correlation (correlation coefficient =0.915; P<0.001) between intracoronary-FFR and intravenous-FFR. Mean FFR was 0.81±0.11 for intracoronary adenosine and 0.81±0.11 for intravenous adenosine (P<0.001). We documented a nonclinically relevant mean difference of 0.006 (limits of agreement: -0.066 to 0.078) between the methods. When stratified by the intracoronary adenosine dose, mean differences between intracoronary and intravenous-FFR amounted to 0.004, 0.011, or 0.000 FFR units for low-dose, intermediate-dose, and high-dose intracoronary adenosine, respectively. Conclusions: The present study documents clinically irrelevant differences in FFR values obtained with intracoronary versus intravenous adenosine. Intracoronary adenosine hence confers a practical and patient-friendly alternative for intravenous adenosine for FFR assessment.
KW - Adenosine/administration & dosage
KW - Cardiac Catheterization
KW - Coronary Artery Disease/diagnosis
KW - Fractional Flow Reserve, Myocardial
KW - Humans
KW - Infusions, Intravenous
KW - Predictive Value of Tests
KW - Reproducibility of Results
KW - Vasodilator Agents/administration & dosage
U2 - 10.1161/CIRCINTERVENTIONS.119.007893
DO - 10.1161/CIRCINTERVENTIONS.119.007893
M3 - Article
C2 - 31870178
SN - 1941-7640
VL - 13
SP - e007893
JO - Circulation. Cardiovascular Interventions
JF - Circulation. Cardiovascular Interventions
IS - 1
ER -