In vitro efficacy and safety of a system for sorbent-assisted peritoneal dialysis

Maaike K van Gelder, Giulia Ligabue, Silvia Giovanella, Elena Bianchini, Frank Simonis, Diënty H M Hazenbrink, Jaap A Joles, Maria A Bajo Rubio, Rafael Selgas, Gianni Cappelli, Karin G F Gerritsen

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

In vitro efficacy and safety of a system for sorbent-assisted peritoneal dialysis. Am J Physiol Renal Physiol 319: F162-F170, 2020. First published June 1, 2020; doi:10.1152/ajprenal. 00079.2020.-A system for sorbent-assisted peritoneal dialysis (SAPD) was designed to continuously recirculate dialysate via a tidal mode using a single lumen peritoneal catheter with regeneration of spent dialysate by means of sorbent technology. We hypothesize that SAPD treatment will maintain a high plasma-to-dialysate concentration gradient and increase the mass transfer area coefficient of solutes. Thereby, the SAPD system may enhance clearance while reducing the number of exchanges. Application is envisaged at night as a bedside device (12 kg, nighttime system). A wearable system (2.0 kg, daytime system) may further enhance clearance during the day. Urea, creatinine, and phosphate removal were studied with the daytime and nighttime system (n = 3 per system) by recirculating 2 liters of spent peritoneal dialysate via a tidal mode (mean flow rate: 50 and 100 mL/min, respectively) for 8 h in vitro. Time-averaged plasma clearance over 24 h was modeled assuming one 2 liter exchange/day, an increase in mass transfer area coefficient, and 0.9 liters ultrafiltration/day. Urea, creatinine, and phosphate removal was 33.2 ± 4.1, 5.3 ± 0.5, and 6.2 ± 1.8 mmol, respectively, with the daytime system and 204 ± 28, 10.3 ± 2.4, and 11.4 ± 2.1 mmol, respectively, with the nighttime system. Time-averaged plasma clearances of urea, creatinine and phosphate were 9.6 ± 1.1, 9.6 ± 1.7, and 7.0 ± 0.9 mL/min, respectively, with the nighttime system and 10.8 ± 1.1, 13.4 ± 1.8, and 9.7 ± 1.6 mL/min, respectively, with the daytime and nighttime system. SAPD treatment may improve removal of uremic toxins compared with conventional peritoneal dialysis, provided that peritoneal mass transport will increase.

Original languageEnglish
Pages (from-to)F162-F170
JournalAmerican journal of physiology. Renal physiology
Volume319
Issue number2
DOIs
Publication statusPublished - 1 Aug 2020

Keywords

  • biocompatibility
  • cytotoxicity tests
  • kidneys
  • peritoneal dialysis
  • sorbent

Fingerprint

Dive into the research topics of 'In vitro efficacy and safety of a system for sorbent-assisted peritoneal dialysis'. Together they form a unique fingerprint.

Cite this