Image quality and radiation dose of coronary CT angiography performed with whole-heart coverage CT scanner with intra-cycle motion correction algorithm in patients with atrial fibrillation

Daniele Andreini*, Gianluca Pontone, Saima Mushtaq, Maria Elisabetta Mancini, Edoardo Conte, Marco Guglielmo, Valentina Volpato, Andrea Annoni, Andrea Baggiano, Alberto Formenti, Valentina Ditali, Marco Perchinunno, Cesare Fiorentini, Antonio L. Bartorelli, Mauro Pepi

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Objectives: To evaluate image quality, coronary evaluability and radiation exposure of coronary CT angiography (CCTA) performed with whole-heart coverage cardiac-CT in patients with atrial fibrillation (AF). Materials and methods: We prospectively enrolled 164 patients with AF who underwent a clinically indicated CCTA with a 16-cm z-axis coverage scanner. In all patients CCTA was performed using prospective ECG-triggering with targeted RR interval. We evaluated image quality, coronary evaluability and effective dose (ED). Patients were divided in two subgroups based on heart rate (HR) during imaging. Group 1: 64 patients with low HR (OpenSPiltSPi75 bpm), group 2: 100 patients with high HR (≥75 bpm). Written informed consent was obtained from all patients and the institutional ethics committee approved the study protocol. Results: In a segment-based analysis, coronary evaluability was 98.4 % (2,577/2,620 segments) in the whole population, without significant differences between groups (1,013/1,024 (98.9 %) and 1,565/1,596 (98.1 %), for groups 1 and 2, respectively, p=0.15). Mean ED was similar in both groups (3.8±1.9 mSv and 3.9±2.1 mSv in groups 1 and 2, respectively, p=0.75) Conclusions: The whole-heart-coverage scanner could evaluate coronary arteries with high image quality and without increase in radiation exposure in AF patients, even in the high HR group. Key points: • Last-generation CT scanner improves coronary artery assessment in AF patients. • The new CT scanner enables low radiation exposure in AF patients. • Diagnostic ICA maybe avoided in AF patients with suspected CAD. • Whole-heart coverage CT scanner enables low radiation exposure in AF patients.

Original languageEnglish
Pages (from-to)1383-1392
Number of pages10
JournalEuropean Radiology
Volume28
Issue number4
DOIs
Publication statusPublished - 1 Apr 2018
Externally publishedYes

Keywords

  • Atrial fibrillation
  • Coronary CT angiography
  • Coronary evaluability
  • Image quality
  • Radiation dose

Fingerprint

Dive into the research topics of 'Image quality and radiation dose of coronary CT angiography performed with whole-heart coverage CT scanner with intra-cycle motion correction algorithm in patients with atrial fibrillation'. Together they form a unique fingerprint.

Cite this