TY - JOUR
T1 - High Irritation and Removal Rates After Plate or Nail Fixation in Patients With Displaced Midshaft Clavicle Fractures
AU - Hulsmans, Martijn H J
AU - van Heijl, Mark
AU - Houwert, R. Marijn
AU - Hammacher, Eric R.
AU - Meylaerts, Sven A.G.
AU - Verhofstad, Michiel H J
AU - Dijkgraaf, Marcel G. W.
AU - Verleisdonk, Egbert Jan M M
N1 - Funding Information:
The institution of one or more of the authors (FJW, RMH, EJV) has received, during the study period, funding from the AO Foundation ((Dübendorf, Switzerland). All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research® editors and board members are on file with the publication and can be viewed on request. Each author certifies that his institution approved the human protocol for this investigation, that all investigations were conducted in conformity with ethical principles of research, and that informed consent for participation in the study was obtained. This work was performed at the Diakonessenhuis Utrecht, Utrecht, The Netherlands; Academic Medical Center, Amsterdam, The Netherlands; St Elisabeth Hospital, Tilburg, The Netherlands; Haaglanden Medical Center, The Hague, The Netherlands; and the St Antonius Hospital, Nieuwegein, The Netherlands.
Publisher Copyright:
© 2016, The Association of Bone and Joint Surgeons®.
PY - 2017/2/1
Y1 - 2017/2/1
N2 - Background: Studies comparing plate with intramedullary nail fixation of displaced midshaft clavicle fractures show faster recovery in the plate group and implant-related complications in both groups after short-term followup (6 or 12 months). Knowledge of disability, complications, and removal rates beyond the first postoperative year will help surgeons in making a decision regarding optimal implant choice. However, comparative studies with followup beyond the first year or two are scarce. Questions/purposes: We asked: (1) Does plate fixation or intramedullary nail fixation for displaced midshaft clavicle fractures result in less disability? (2) Which type of fixation, plate or intramedullary, is more frequently associated with implant-related irritation and implant removal? (3) Is plate or intramedullary fixation associated with postoperative complications beyond the first postoperative year? Methods: Between January 2011 and August 2012, patients with displaced midshaft clavicle fractures were enrolled and randomized to plate or intramedullary nail fixation. A total of 58 patients with plate and 62 patients with intramedullary nails initially were enrolled. Minimum followup was 30 months (mean, 39 months; range, 30–51 months). Two patients (3%) with plate fixation and two patients (3%) with intramedullary nails were lost to followup. The QuickDASH was obtained at final followup and compared between patients who had plate fixation and those who had intramedullary nail fixation. Postoperative complications measured include infection, implant-related irritation, implant failure, nonunion, and refracture after implant removal. Indications for implant removal included implant-related irritation, implant failure, nonunion, patient’s wish, or surgeon’s preference. Results: Between patients with plate versus intramedullary nail fixation, there were no differences in QuickDASH scores (plate, 1.8 ± 3.6; intramedullary nail, 1.8 ± 7.2; mean difference, −0.7; 95% CI, −2.2 to 2.04; p = 0.95). The proportion of patients having implant-related irritation was not different (39 of 56 [70%] versus 41 of 62 [66%]; relative risk, 1.05; 95% CI, 0.82–1.35; p = 0.683). Intramedullary fixation was associated with a higher likelihood of implant removal (51 of 62 [82%] versus 28 of 56 [50%]; relative risk, 1.65; 95% CI, 1.24–2.19; p < 0.001). Among the removed implants more plates than intramedullary nails were removed after the 1-year followup (12 of 28 [43%] versus six of 51 [12%]; p = 0.002). There were no infections, implant breakage, nonunions, or refractures between the 1-year and final followup in either group. Conclusions: After a mean followup of 39 months, disability scores were excellent. Major complications did not occur after the 1-year followup. A frequent and bothersome problem after both surgical treatments is implant-related irritation, resulting in high rates of implant removal, after 1 year. Future research could focus on analyzing risk factors for implant irritation or removal. Level of Evidence: Level II, therapeutic study.
AB - Background: Studies comparing plate with intramedullary nail fixation of displaced midshaft clavicle fractures show faster recovery in the plate group and implant-related complications in both groups after short-term followup (6 or 12 months). Knowledge of disability, complications, and removal rates beyond the first postoperative year will help surgeons in making a decision regarding optimal implant choice. However, comparative studies with followup beyond the first year or two are scarce. Questions/purposes: We asked: (1) Does plate fixation or intramedullary nail fixation for displaced midshaft clavicle fractures result in less disability? (2) Which type of fixation, plate or intramedullary, is more frequently associated with implant-related irritation and implant removal? (3) Is plate or intramedullary fixation associated with postoperative complications beyond the first postoperative year? Methods: Between January 2011 and August 2012, patients with displaced midshaft clavicle fractures were enrolled and randomized to plate or intramedullary nail fixation. A total of 58 patients with plate and 62 patients with intramedullary nails initially were enrolled. Minimum followup was 30 months (mean, 39 months; range, 30–51 months). Two patients (3%) with plate fixation and two patients (3%) with intramedullary nails were lost to followup. The QuickDASH was obtained at final followup and compared between patients who had plate fixation and those who had intramedullary nail fixation. Postoperative complications measured include infection, implant-related irritation, implant failure, nonunion, and refracture after implant removal. Indications for implant removal included implant-related irritation, implant failure, nonunion, patient’s wish, or surgeon’s preference. Results: Between patients with plate versus intramedullary nail fixation, there were no differences in QuickDASH scores (plate, 1.8 ± 3.6; intramedullary nail, 1.8 ± 7.2; mean difference, −0.7; 95% CI, −2.2 to 2.04; p = 0.95). The proportion of patients having implant-related irritation was not different (39 of 56 [70%] versus 41 of 62 [66%]; relative risk, 1.05; 95% CI, 0.82–1.35; p = 0.683). Intramedullary fixation was associated with a higher likelihood of implant removal (51 of 62 [82%] versus 28 of 56 [50%]; relative risk, 1.65; 95% CI, 1.24–2.19; p < 0.001). Among the removed implants more plates than intramedullary nails were removed after the 1-year followup (12 of 28 [43%] versus six of 51 [12%]; p = 0.002). There were no infections, implant breakage, nonunions, or refractures between the 1-year and final followup in either group. Conclusions: After a mean followup of 39 months, disability scores were excellent. Major complications did not occur after the 1-year followup. A frequent and bothersome problem after both surgical treatments is implant-related irritation, resulting in high rates of implant removal, after 1 year. Future research could focus on analyzing risk factors for implant irritation or removal. Level of Evidence: Level II, therapeutic study.
UR - https://www.scopus.com/pages/publications/84994473917
U2 - 10.1007/s11999-016-5113-8
DO - 10.1007/s11999-016-5113-8
M3 - Article
C2 - 27830484
AN - SCOPUS:84994473917
SN - 0009-921X
VL - 475
SP - 532
EP - 539
JO - Clinical Orthopaedics and Related Research
JF - Clinical Orthopaedics and Related Research
IS - 2
ER -