TY - JOUR
T1 - Haemodynamic effects of patent foramen ovale and atrial septal defect closure
T2 - A comparison during percutaneous shunt closure
AU - Luermans, Justin G L M
AU - Bos, Willem J W
AU - Post, Martijn C.
AU - ten Berg, Jurriën M.
AU - Thijs Plokker, H. W.
AU - Suttorp, Maarten J.
PY - 2010/1/1
Y1 - 2010/1/1
N2 - Objectives: We investigated the haemodynamic effect of percutaneous closure of an intra-atrial shunt, using non-invasive finger pressure measurements. Background: Percutaneous closure of both patent foramen ovale (PFO) and atrial septal defect (ASD) is widely practised. Currently no data are available on short-term haemodynamic changes induced by closure. Methods: Twenty-five consecutive patients (mean age 49 ± 17 years, 10 men) who underwent a percutaneous closure of a PFO (n = 15) or ASD (n = 10) were included in this study. During the procedure blood pressure and heart rate (HR) were monitored continuously with a Finometer®. Changes in systolic, mean, and diastolic pressure, stroke volume (SV), cardiac output (CO) and total peripheral resistance (TPR) were computed from the pressure registrations using Modelflow® methodology. Results: Baseline characteristics were similar for the PFO and ASD patients. After PFO closure none of the haemodynamic parameters changed significantly. After ASD closure the systolic, mean, and diastolic pressures increased 7·1 ± 5·4 (P = 0·003), 3·8 ± 3·5 (P = 0·007) and 2·0 ± 3·0 mmHg (P = ns) respectively. HR decreased 5·1 ± 5·3 beats per minute (P = 0·01). SV, CO and TPR increased 8·5 ± 6·4 ml (13·5%; P = 0·002), 0·21 ± 0·45 l min-1 (5·6%; P = ns) and 0·02 ± 0·14 dynes (4·1%; P = ns) respectively. The changes in SV differ between the PFO and ASD patients (P = 0·009). Conclusions: Using non-invasive finger pressure measurements, we found that SV, mean and systolic blood pressure increased immediately after percutaneous closure of an ASD in adults, whereas the percutaneous PFO closure had no effect on haemodynamic characteristics.
AB - Objectives: We investigated the haemodynamic effect of percutaneous closure of an intra-atrial shunt, using non-invasive finger pressure measurements. Background: Percutaneous closure of both patent foramen ovale (PFO) and atrial septal defect (ASD) is widely practised. Currently no data are available on short-term haemodynamic changes induced by closure. Methods: Twenty-five consecutive patients (mean age 49 ± 17 years, 10 men) who underwent a percutaneous closure of a PFO (n = 15) or ASD (n = 10) were included in this study. During the procedure blood pressure and heart rate (HR) were monitored continuously with a Finometer®. Changes in systolic, mean, and diastolic pressure, stroke volume (SV), cardiac output (CO) and total peripheral resistance (TPR) were computed from the pressure registrations using Modelflow® methodology. Results: Baseline characteristics were similar for the PFO and ASD patients. After PFO closure none of the haemodynamic parameters changed significantly. After ASD closure the systolic, mean, and diastolic pressures increased 7·1 ± 5·4 (P = 0·003), 3·8 ± 3·5 (P = 0·007) and 2·0 ± 3·0 mmHg (P = ns) respectively. HR decreased 5·1 ± 5·3 beats per minute (P = 0·01). SV, CO and TPR increased 8·5 ± 6·4 ml (13·5%; P = 0·002), 0·21 ± 0·45 l min-1 (5·6%; P = ns) and 0·02 ± 0·14 dynes (4·1%; P = ns) respectively. The changes in SV differ between the PFO and ASD patients (P = 0·009). Conclusions: Using non-invasive finger pressure measurements, we found that SV, mean and systolic blood pressure increased immediately after percutaneous closure of an ASD in adults, whereas the percutaneous PFO closure had no effect on haemodynamic characteristics.
KW - Atrial septal defect
KW - Finometer
KW - Haemodynamics
KW - Patent foramen ovale
KW - Transcatheter closure
UR - http://www.scopus.com/inward/record.url?scp=72549097835&partnerID=8YFLogxK
U2 - 10.1111/j.1475-097X.2009.00905.x
DO - 10.1111/j.1475-097X.2009.00905.x
M3 - Article
C2 - 19804419
AN - SCOPUS:72549097835
SN - 1475-0961
VL - 30
SP - 64
EP - 68
JO - Clinical Physiology and Functional Imaging
JF - Clinical Physiology and Functional Imaging
IS - 1
ER -