Haemodynamic effects of patent foramen ovale and atrial septal defect closure: A comparison during percutaneous shunt closure

Justin G L M Luermans, Willem J W Bos, Martijn C. Post*, Jurriën M. ten Berg, H. W. Thijs Plokker, Maarten J. Suttorp

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

2 Citations (Scopus)

Abstract

Objectives: We investigated the haemodynamic effect of percutaneous closure of an intra-atrial shunt, using non-invasive finger pressure measurements. Background: Percutaneous closure of both patent foramen ovale (PFO) and atrial septal defect (ASD) is widely practised. Currently no data are available on short-term haemodynamic changes induced by closure. Methods: Twenty-five consecutive patients (mean age 49 ± 17 years, 10 men) who underwent a percutaneous closure of a PFO (n = 15) or ASD (n = 10) were included in this study. During the procedure blood pressure and heart rate (HR) were monitored continuously with a Finometer®. Changes in systolic, mean, and diastolic pressure, stroke volume (SV), cardiac output (CO) and total peripheral resistance (TPR) were computed from the pressure registrations using Modelflow® methodology. Results: Baseline characteristics were similar for the PFO and ASD patients. After PFO closure none of the haemodynamic parameters changed significantly. After ASD closure the systolic, mean, and diastolic pressures increased 7·1 ± 5·4 (P = 0·003), 3·8 ± 3·5 (P = 0·007) and 2·0 ± 3·0 mmHg (P = ns) respectively. HR decreased 5·1 ± 5·3 beats per minute (P = 0·01). SV, CO and TPR increased 8·5 ± 6·4 ml (13·5%; P = 0·002), 0·21 ± 0·45 l min-1 (5·6%; P = ns) and 0·02 ± 0·14 dynes (4·1%; P = ns) respectively. The changes in SV differ between the PFO and ASD patients (P = 0·009). Conclusions: Using non-invasive finger pressure measurements, we found that SV, mean and systolic blood pressure increased immediately after percutaneous closure of an ASD in adults, whereas the percutaneous PFO closure had no effect on haemodynamic characteristics.

Original languageEnglish
Pages (from-to)64-68
Number of pages5
JournalClinical Physiology and Functional Imaging
Volume30
Issue number1
DOIs
Publication statusPublished - 1 Jan 2010

Keywords

  • Atrial septal defect
  • Finometer
  • Haemodynamics
  • Patent foramen ovale
  • Transcatheter closure