First evaluation of the feasibility of MLC tracking using ultrasound motion estimation

Martin F. Fast, Tuathan P. O'Shea, Simeon Nill, Uwe Oelfke, Emma J. Harris

Research output: Contribution to journalArticleAcademicpeer-review

24 Citations (Scopus)

Abstract

Purpose: To quantify the performance of the Clarity ultrasound (US) imaging system (Elekta AB, Stockholm, Sweden) for real-time dynamic multileaf collimator (MLC) tracking. Methods: The Clarity calibration and quality assurance phantom was mounted on a motion platform moving with a periodic sine wave trajectory. The detected position of a 30 mm hypoechogenic sphere within the phantom was continuously reported via Claritys real-time streaming interface to an in-house tracking and delivery software and subsequently used to adapt the MLC aperture. A portal imager measured MV treatment field/MLC apertures and motion platform positions throughout each experiment to independently quantify system latency and geometric error. Based on the measured range of latency values, a prostate stereotactic body radiation therapy (SBRT) delivery was performed with three realistic motion trajectories. The dosimetric impact of system latency on MLC tracking was directly measured using a 3D dosimeter mounted on the motion platform. Results: For 2D US imaging, the overall system latency, including all delay times from the imaging and delivery chain, ranged from 392 to 424 ms depending on the lateral sector size. For 3D US imaging, the latency ranged from 566 to 1031 ms depending on the elevational sweep. The latencycorrected geometric root-mean squared error was below 0.75 mm (2D US) and below 1.75 mm (3D US). For the prostate SBRT delivery, the impact of a range of system latencies (4001000 ms) on the MLC tracking performance was minimal in terms of gamma failure rate. Conclusions: Real-time MLC tracking based on a noninvasive US input is technologically feasible. Current system latencies are higher than those for x-ray imaging systems, but US can provide full volumetric image data and the impact of system latency was measured to be small for a prostate SBRT case when using a US-like motion input.

Original languageEnglish
Article number4955440
JournalMedical Physics
Volume43
Issue number8
DOIs
Publication statusPublished - 1 Aug 2016

Keywords

  • MLC
  • motion management
  • multileaf collimator
  • real-time tumor tracking
  • ultrasound

Fingerprint

Dive into the research topics of 'First evaluation of the feasibility of MLC tracking using ultrasound motion estimation'. Together they form a unique fingerprint.

Cite this