Skip to main navigation Skip to search Skip to main content

Evaluation of brachytherapy applicators and their association with morbidity and local control in cervix cancer: An EMBRACE I analysis

  • M. Serban*
  • , S. Spampinato
  • , A. de Leeuw
  • , I. Fortin
  • , C. Kirisits
  • , X. Y. Ye
  • , M. Schmid
  • , P. Hoskin
  • , U. Mahantshetty
  • , B. Segedin
  • , K. Bruheim
  • , F. Huang
  • , R. Bhavana
  • , R. Cooper
  • , Van Der Steen Banasik E
  • , E. Van Limbergen
  • , B. R. Pieters
  • , LT T. Tan
  • , S. Chopra
  • , R. Nout
  • N. Nesvacil, K. Kirchheiner, R. Pötter, I. M. Jürgenliemk-Schulz, K. Tanderup
*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

2 Downloads (Pure)

Abstract

Purpose: To investigate the effects of brachytherapy (BT) applicator and implant type on morbidity and local control (LC) in locally advanced cervix cancer patients. Methods: 1071 patients treated with radiochemotherapy including MRI-guided BT using tandem&ring (T&R) or tandem&ovoids (T&O) from 19 EMBRACE-I centers were analyzed. Intracavitary (IC) or intracavitary/interstitial (IC/IS) implants were used. Centers came from different brachytherapy traditions and followed their institutional dose aims and planning strategies. LC and physician-assessed morbidity (median follow-up 48 months) was compared between applicator/implant types using Cox proportional hazard model adjusting for patient characteristics and treatment-related potential confounders. Moderate-to-severe (G ≥ 2) genito-urinary (cystitis/frequency/incontinence), gastro-intestinal (proctitis/bleeding/diarrhea) and vaginal (stenosis/mucositis) symptoms were analysed individually. Severe events (G ≥ 3) were pooled per organ. Results: The T&O (n = 346) compared to T&R (n = 725) had a higher risk of morbidity, with HRs > 1.3 in 14/16 individual G ≥ 2 symptoms and in 3/4 G ≥ 3 pooled organ symptoms. Patients treated with IC/IS (n = 512) compared to IC (n = 559) were not at higher risk of G ≥ 2 symptoms, with HRs < 1 in 6/8 MVAs. Crude incidence of local failure was 7.3 % (25/343) for T&O and 6.6 % (47/712) for T&R. Conclusions: In this patient cohort, treated between 2008–2015, T&R and T&O demonstrated comparable LC. However, a higher risk of morbidity is reported for T&O. This increased risk was partly explained by hotspot doses, with factors such as irradiated volumes and organ irradiation length also contributing. Additionally, implant quality, dose planning aims and strategies, and morbidity reporting may have impacted the observed differences in morbidity. IC/IS applicators did not increase morbidity risk compared to IC applicators.

Original languageEnglish
Article number110954
Number of pages9
JournalRadiotherapy and Oncology
Volume210
DOIs
Publication statusPublished - Sept 2025

Keywords

  • Brachytherapy applicators
  • Cervical cancer
  • EMBRACE study
  • Local control outcomes
  • Morbidity outcomes
  • MR-guided brachytherapy
  • Tandem and Ovoids
  • Tandem and Ring

Fingerprint

Dive into the research topics of 'Evaluation of brachytherapy applicators and their association with morbidity and local control in cervix cancer: An EMBRACE I analysis'. Together they form a unique fingerprint.

Cite this