TY - JOUR
T1 - Evaluation of a crystalline sirolimus-eluting coronary stent with a bioabsorbable polymer designed for rapid dissolution
T2 - Two-year outcomes from the DESSOLVE i and II trials
AU - Wijns, William
AU - Suttorp, Maarten Jan
AU - Zagozdzon, Leszek
AU - Morice, Marie Claude
AU - McClean, Dougal
AU - Stella, Pieter
AU - Donohoe, Dennis
AU - Knape, Charlene
AU - Ormiston, John
PY - 2016/6/1
Y1 - 2016/6/1
N2 - Aims: Our aim was to evaluate the two-year clinical results of a new sirolimus-eluting stent (MiStent SES) with a bioabsorbable coating designed for rapid polymer dissolution but sustained drug delivery. Methods and results: Major adverse cardiac events (MACE), target lesion failure (TLF), target vessel failure (TVF), and stent thrombosis (ST) at two-year follow-up are reported for the DESSOLVE I and II trials. In DESSOLVE I, the MiStent SES (n=29) demonstrated a 3.4% two-year MACE rate without TLF or TVF. In DESSOLVE II, the MiStent group had a 6.7% (8/120) two-year MACE rate compared to 13.3% (8/60) for Endeavor (p=0.167). TLF was 5.0% in the MiStent and Endeavor groups (p=1.00). TVF was 5.0% for MiStent versus 11.7% for Endeavor (p=0.129). No probable or definite ST was reported with the MiStent up to two years. The median duration of dual antiplatelet therapy (DAPT) in DESSOLVE I and II was 364 and 366 days, respectively. Conclusions: The MiStent SES demonstrated good long-term safety and effectiveness with low two-year MACE, TLF, and TVF rates.
AB - Aims: Our aim was to evaluate the two-year clinical results of a new sirolimus-eluting stent (MiStent SES) with a bioabsorbable coating designed for rapid polymer dissolution but sustained drug delivery. Methods and results: Major adverse cardiac events (MACE), target lesion failure (TLF), target vessel failure (TVF), and stent thrombosis (ST) at two-year follow-up are reported for the DESSOLVE I and II trials. In DESSOLVE I, the MiStent SES (n=29) demonstrated a 3.4% two-year MACE rate without TLF or TVF. In DESSOLVE II, the MiStent group had a 6.7% (8/120) two-year MACE rate compared to 13.3% (8/60) for Endeavor (p=0.167). TLF was 5.0% in the MiStent and Endeavor groups (p=1.00). TVF was 5.0% for MiStent versus 11.7% for Endeavor (p=0.129). No probable or definite ST was reported with the MiStent up to two years. The median duration of dual antiplatelet therapy (DAPT) in DESSOLVE I and II was 364 and 366 days, respectively. Conclusions: The MiStent SES demonstrated good long-term safety and effectiveness with low two-year MACE, TLF, and TVF rates.
KW - Bioabsorbable polymer
KW - Drug-eluting coronary stent
KW - Sirolimus
UR - http://www.scopus.com/inward/record.url?scp=84975862689&partnerID=8YFLogxK
U2 - 10.4244/EIJY15M09_14
DO - 10.4244/EIJY15M09_14
M3 - Article
C2 - 26403639
SN - 1774-024X
VL - 12
SP - 352
EP - 355
JO - EuroIntervention
JF - EuroIntervention
IS - 3
ER -