Abstract
BACKGROUND: Change in left ventricular end-systolic volume (∆LVESV) is the most frequently used surrogate marker in measuring response to cardiac resynchronisation therapy (CRT). We investigated whether ∆LVESV is the best measure to discriminate between a favourable and unfavourable outcome and whether this is equally applicable to non-ischaemic and ischaemic cardiomyopathy.
METHODS: 205 CRT patients (age 65 ± 12 years, 69 % men) were included. At baseline and 6 months echocardiographic studies, exercise testing and laboratory measurements were performed. CRT response was assessed by: ∆LVESV, ∆LV ejection fraction (LVEF), ∆ interventricular mechanical delay, ∆VO2 peak, ∆VE/VCO2, ∆BNP, ∆creatinine, ∆NYHA, and ∆QRS. These were correlated to the occurrence of major adverse cardiac events (MACE) between 6 and 24 months.
RESULTS: MACE occurred in 19 % of the patients (non-ischaemic: 13 %, ischaemic: 24 %). ∆LVESV remained the only surrogate marker for CRT response for the total population and patients with non-ischaemic cardiomyopathy, showing areas under the curve (AUC) of 0.69 and 0.850, respectively. For ischaemic cardiomyopathy, ∆BNP was the best surrogate marker showing an AUC of 0.66.
CONCLUSION: ∆LVESV is an excellent surrogate marker measuring CRT response concerning long-term outcome for non-ischaemic cardiomyopathy. ∆LVESV is not suitable for ischaemic cardiomyopathy in which measuring CRT response remains difficult.
Original language | English |
---|---|
Pages (from-to) | 47-55 |
Number of pages | 9 |
Journal | Netherlands Heart Journal |
Volume | 24 |
Issue number | 1 |
DOIs | |
Publication status | Published - Jan 2016 |
Keywords
- Cardiac resynchronisation therapy
- Surrogate markers