Background We aimed to compare the rate of neurological events in patients with or without cerebral embolic protection (CEP) during transcatheter aortic valve replacement (TAVR). Methods and Results Data on clinical end points including neurological events ≤30 days post-TAVR were collected for all patients who underwent transfemoral TAVR in 2 academic tertiary care institutions. Patients were matched through propensity scoring, which resulted in 333 pairs of patients with versus without CEP out of a total of 831 consecutive patients. The median age was 81 (76-85) years, and the median logistic EuroScore was 14% (9%-20%). The CEP group experienced less neurological events at 24 hours (1% versus 4%; P=0.035) and at 30 days (3% versus 7%; P=0.029). There were significantly more disabling strokes in unprotected patients at 30 days (1% versus 4%; P=0.039). CEP was associated with significantly fewer neurological events at 24 hours after TAVR (odds ratio, 0.20; 95% CI, 0.06-0.73; P=0.015) by multiple regression analysis, while age and valve type did not contribute significantly. Overall, 67% (2 of 3) in the CEP versus 83% (10 of 12) in the non-CEP cohort experienced neurological events in protected areas (ie, not dependent on the left vertebral artery). Conclusions The use of filter-based CEP during TAVR was associated with less neurological events, especially in CEP-protected brain territories.

Original languageEnglish
Pages (from-to)e007605
JournalCirculation. Cardiovascular Interventions
Volume12
Issue number6
DOIs
Publication statusPublished - Jun 2019
Externally publishedYes

Keywords

  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis/diagnostic imaging
  • Embolic Protection Devices
  • Female
  • Heart Valve Prosthesis
  • Humans
  • Intracranial Embolism/diagnostic imaging
  • Male
  • Netherlands
  • Protective Factors
  • Registries
  • Retrospective Studies
  • Risk Factors
  • Stroke/diagnostic imaging
  • Time Factors
  • Transcatheter Aortic Valve Replacement/adverse effects
  • Treatment Outcome

Fingerprint

Dive into the research topics of 'Early Clinical Impact of Cerebral Embolic Protection in Patients Undergoing Transcatheter Aortic Valve Replacement'. Together they form a unique fingerprint.

Cite this