T1 - Device Adjustment and Recovery in Patients With Heart Failure Undergoing a Cardiac Resynchronization Therapy Implantation
T2 - A Longitudinal Study
AU - Thylén, Ingela
AU - Jaarsma, Tiny
AU - Ingadottir, Brynja
N1 - Publisher Copyright:
Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved
PY - 2021/3/4
Y1 - 2021/3/4
N2 - Background: Little is known about risk factors for poor adjustment to the device after cardiac resynchronization therapy (CRT) implantation in patients with heart failure. Purpose: The aim of this study was to explore device adjustment and the postoperative recovery of patients with heart failure undergoing elective CRT device implantation. Methods: In this prospective multicenter longitudinal study, data were collected before implantation and after 2 weeks, 6 months, and 1 year, using validated self-reported instruments and investigator-designed, CRT-specific questions. Results: A total of 133 patients, 79% male, with a mean age of 70 ± 10 years, were included. Patients adjusted to the device over time (P < .001), but 20% of patients had difficulties after 2 weeks, and 11% had difficulties at the 1-year follow-up. Fatigue was the most common health problem before surgery (87%), which was reduced to 65% after 1 year, P < .001. Patients' recovery improved over time (P < .001). Device-specific problems with hiccups (7% vs 14%), pulsation around the device (29% vs 24%), tachycardia (28% vs 29%), appearance of the scar (21% vs 17%), and the device bulging out (65% vs 61%) remained unchanged over time, whereas stiffness in the shoulder (64% vs 28%, P < .001) and wound healing (9% vs 2%, P < .05) improved. Conclusions: Most patients with heart failure recover and adjust early after their CRT implantation and improve even more during follow-up. However, recovery and adjustment are problematic for some patients, and many experience bodily discomforts because of the device. Early screening for poor adjustment and psychological distress can lead to appropriate interventions and timely referrals. This is important in the era of remote monitoring with less face-to-face contact.
AB - Background: Little is known about risk factors for poor adjustment to the device after cardiac resynchronization therapy (CRT) implantation in patients with heart failure. Purpose: The aim of this study was to explore device adjustment and the postoperative recovery of patients with heart failure undergoing elective CRT device implantation. Methods: In this prospective multicenter longitudinal study, data were collected before implantation and after 2 weeks, 6 months, and 1 year, using validated self-reported instruments and investigator-designed, CRT-specific questions. Results: A total of 133 patients, 79% male, with a mean age of 70 ± 10 years, were included. Patients adjusted to the device over time (P < .001), but 20% of patients had difficulties after 2 weeks, and 11% had difficulties at the 1-year follow-up. Fatigue was the most common health problem before surgery (87%), which was reduced to 65% after 1 year, P < .001. Patients' recovery improved over time (P < .001). Device-specific problems with hiccups (7% vs 14%), pulsation around the device (29% vs 24%), tachycardia (28% vs 29%), appearance of the scar (21% vs 17%), and the device bulging out (65% vs 61%) remained unchanged over time, whereas stiffness in the shoulder (64% vs 28%, P < .001) and wound healing (9% vs 2%, P < .05) improved. Conclusions: Most patients with heart failure recover and adjust early after their CRT implantation and improve even more during follow-up. However, recovery and adjustment are problematic for some patients, and many experience bodily discomforts because of the device. Early screening for poor adjustment and psychological distress can lead to appropriate interventions and timely referrals. This is important in the era of remote monitoring with less face-to-face contact.
KW - adjustment disorders
KW - cardiac resynchronization therapy devices
KW - defibrillators
KW - heart failure
KW - implantable
KW - minor surgical procedures
UR - http://www.scopus.com/inward/record.url?scp=85128488176&partnerID=8YFLogxK
U2 - 10.1097/JCN.0000000000000795
DO - 10.1097/JCN.0000000000000795
M3 - Article
C2 - 33657066
SN - 1474-5151
VL - 37
SP - 221
EP - 230
JO - European Journal of Cardiovascular Nursing
JF - European Journal of Cardiovascular Nursing
IS - 3
ER -