TY - JOUR
T1 - Detectability and intra-fraction motion of individual elective lymph nodes in head and neck cancer patients on the Magnetic Resonance Image guided linear accelerator
AU - Reinders, Floris C.J.
AU - de Ridder, Mischa
AU - Stijnman, Peter R.S.
AU - Doornaert, Patricia A.H.
AU - Raaijmakers, Cornelis P.J.
AU - Philippens, Marielle E.P.
N1 - Publisher Copyright:
© 2024
PY - 2024/1
Y1 - 2024/1
N2 - Background and purpose: Individual elective lymph node irradiation instead of elective neck irradiation is a new concept for head-and-neck cancer (HNC) patients developed for the Magnetic Resonance Image guided linear accelerator (MR-linac). To prepare this, the detectability, volume changes and intra-fraction motion of elective lymph nodes on the MR-linac was assessed. Materials and methods: A total of 15 HNC patients underwent diagnostic pre-treatment MRI. Additionally, two MR-linac scans were obtained with a 10-minute time difference in the first week of radiation treatment. Elective lymph node contours inside lymph node levels (Ib-V) were segmented on the pre-treatment MRI and the MR-linac scans and compared on number and maximal transversal diameter. Intra-fraction motion of elective lymph nodes on the MR-linac was estimated using Center of Mass (COM) distances and incremental isotropic expansion of lymph node segmentations. Results: Of all 679 detected lymph nodes on the pre-treatment MRI, eight lymph nodes were not detectable on the first MR-linac scan and 16 new lymph nodes were detected. Lymph node diameters between the pre-treatment MRI scan and the MR-linac scan varied from −0.19 to + 0.13 mm. COM distances varied from 1.2 to 1.7 mm and lymph node contours had to be expanded with 3 mm. Conclusions: Nearly all elective lymph nodes were detectable on the 1.5T MR-linac scan with no major changes in target volumes compared to the pre-treatment MRI. Simulated intra-fraction motion during the MR-linac scans was smaller than the 5-mm margin that will be used in the first elective lymph node radiation treatment.
AB - Background and purpose: Individual elective lymph node irradiation instead of elective neck irradiation is a new concept for head-and-neck cancer (HNC) patients developed for the Magnetic Resonance Image guided linear accelerator (MR-linac). To prepare this, the detectability, volume changes and intra-fraction motion of elective lymph nodes on the MR-linac was assessed. Materials and methods: A total of 15 HNC patients underwent diagnostic pre-treatment MRI. Additionally, two MR-linac scans were obtained with a 10-minute time difference in the first week of radiation treatment. Elective lymph node contours inside lymph node levels (Ib-V) were segmented on the pre-treatment MRI and the MR-linac scans and compared on number and maximal transversal diameter. Intra-fraction motion of elective lymph nodes on the MR-linac was estimated using Center of Mass (COM) distances and incremental isotropic expansion of lymph node segmentations. Results: Of all 679 detected lymph nodes on the pre-treatment MRI, eight lymph nodes were not detectable on the first MR-linac scan and 16 new lymph nodes were detected. Lymph node diameters between the pre-treatment MRI scan and the MR-linac scan varied from −0.19 to + 0.13 mm. COM distances varied from 1.2 to 1.7 mm and lymph node contours had to be expanded with 3 mm. Conclusions: Nearly all elective lymph nodes were detectable on the 1.5T MR-linac scan with no major changes in target volumes compared to the pre-treatment MRI. Simulated intra-fraction motion during the MR-linac scans was smaller than the 5-mm margin that will be used in the first elective lymph node radiation treatment.
KW - Elective neck irradiation
KW - Lymph nodes
KW - Magnetic Resonance Imaging
KW - Radiotherapy
KW - Squamous cell carcinoma of head and neck
UR - http://www.scopus.com/inward/record.url?scp=85182976522&partnerID=8YFLogxK
U2 - 10.1016/j.phro.2024.100532
DO - 10.1016/j.phro.2024.100532
M3 - Article
AN - SCOPUS:85182976522
SN - 2405-6316
VL - 29
JO - Physics and Imaging in Radiation Oncology
JF - Physics and Imaging in Radiation Oncology
M1 - 100532
ER -