Skip to main navigation Skip to search Skip to main content

Comparative evaluation of five rapid PCR platforms for respiratory virus detection

  • Pieter W Smit
  • , Peter de Man
  • , Henk Brand
  • , Simone Breijer
  • , Mariska van Wijk
  • , Adam Meijer*
  • , David S Y Ong*
  • *Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

2 Downloads (Pure)

Abstract

BACKGROUND: The demand for rapid molecular diagnostics for respiratory viruses has increased substantially. Several point-of-care PCR platforms have become available, yet comparative performance data remain limited.

OBJECTIVES: To evaluate the diagnostic accuracy and operational reliability of four rapid PCR platforms for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), influenza A and B viruses (IAV, IBV), and respiratory syncytial virus (RSV), in comparison with the GeneXpert (Cepheid, USA) platform.

METHODS: Nasopharyngeal swabs from patients with respiratory symptoms were tested using the GeneXpert, positive samples were subsequently analysed on four alternative systems: the 30-minute and 1-hour M10 (SD Biosensor, South Korea) assays, FlashDetect™ Flash10 (Coyote Bioscience, China), Vivalytic (Bosch Healthcare Solutions, Germany), and Galaxy Lite (Igenesis, China). Additional lower viral load samples and cultured IAV/ IBV strains were included.

RESULTS: A total of 223 GeneXpert positive samples were prospectively analysed. Flash10 showed 94.6% overall agreement, missing SARS-CoV-2 (n = 4, GeneXpert Cycle threshold (Ct) min-max; 37.7-42.2), IAV (n = 5, 32.8-37.7), and IBV (n = 3, 26.5-36.7). Vivalytic showed 83.0% overall agreement, missing SARS-CoV-2 (n = 16, 30.4-42.2), IAV (n = 9, 26.8-37.7), IBV (n = 9, 27.2-36.7), and RSV (n = 4, 31.5-37.0). Galaxy Lite achieved 88.2% overall agreement but failed in 27.2% of test runs. With a smaller sample size the M10 (30-minute) assay showed 98.6% overall agreement with GeneXpert, missing one SARS-CoV-2 case (Ct 39.7).

CONCLUSION: Among four platforms, the M10 (30-min version) and Flash10 platforms demonstrated the highest agreement rates with the GeneXpert. The variability in performance highlights the importance of independent platform evaluation.

Original languageEnglish
Article numbere0338716
Number of pages10
JournalPLoS ONE
Volume20
Issue number12
DOIs
Publication statusPublished - 11 Dec 2025

Keywords

  • COVID-19/diagnosis
  • Humans
  • Influenza A virus/genetics
  • Influenza B virus/genetics
  • Nasopharynx/virology
  • Polymerase Chain Reaction/methods
  • Reproducibility of Results
  • Respiratory Syncytial Viruses/genetics
  • SARS-CoV-2/genetics
  • Sensitivity and Specificity

Fingerprint

Dive into the research topics of 'Comparative evaluation of five rapid PCR platforms for respiratory virus detection'. Together they form a unique fingerprint.

Cite this