Challenges in MR-only seed localization for postimplant dosimetry in permanent prostate brachytherapy

Frank Zijlstra, Rien Moerland, Jochem R N van der Voort van Zyp, Juus L Noteboom, Max A Viergever, Peter R Seevinck

Research output: Contribution to journalArticleAcademicpeer-review

2 Downloads (Pure)

Abstract

Purpose: An MR-only postimplant dosimetry workflow for low dose rate (LDR) brachytherapy could reduce patient burden, improve accuracy, and improve cost efficiency. However, localization of brachytherapy seeds on MRI scans remains a major challenge for this type of workflow. In this study, we propose and validate an MR-only seed localization method and identify remaining challenges. Methods and materials: The localization method was based on template matching of simulations of complex-valued imaging artifacts around metal brachytherapy seeds. The method was applied to MRI scans of 25 prostate cancer patients who underwent LDR brachytherapy and for whom postimplant dosimetry was performed after 4 weeks. The seed locations found with the MR-only method were validated against the seed locations found on CT. The circumstances in which detection errors were made were classified to gain an insight in the nature of the errors. Results: A total of 1490 of 1557 (96%) seeds were correctly detected, while 67 false-positive errors were made. The correctly detected seed locations had a high spatial accuracy with an average error of 0.8 mm compared with CT. A majority of the false positives occurred near other seeds. Most false negatives were found in either stranded configurations without spacers or near other seeds. Conclusions: The low detection error rate and high localization accuracy obtained by the complex-valued template matching approach are promising for future clinical application of MR-only dosimetry. The most important remaining challenge is robustness with regard to configurations of multiple seeds in close vicinity, such as in strands of seeds without spacers. This issue could potentially be resolved by simulating specific configurations of multiple seeds or by constraining the treatment planning to avoid these configurations, which could make the proposed method competitive with CT-based seed localization.

Original languageEnglish
Pages (from-to)5051-5060
Number of pages10
JournalMedical Physics
Volume44
Issue number10
DOIs
Publication statusPublished - Oct 2017

Keywords

  • MRI
  • brachytherapy
  • seed localization
  • simulation
  • susceptibility
  • template matching

Fingerprint

Dive into the research topics of 'Challenges in MR-only seed localization for postimplant dosimetry in permanent prostate brachytherapy'. Together they form a unique fingerprint.

Cite this