TY - JOUR
T1 - Cardiac resynchronization therapy with or without defibrillator in patients with heart failure
AU - Schrage, Benedikt
AU - Lund, Lars H
AU - Melin, Michael
AU - Benson, Lina
AU - Uijl, Alicia
AU - Dahlström, Ulf
AU - Braunschweig, Frieder
AU - Linde, Cecilia
AU - Savarese, Gianluigi
N1 - Publisher Copyright:
© 2021 The Author(s). Published by Oxford University Press on behalf of the European Society of Cardiology.
PY - 2022/1/1
Y1 - 2022/1/1
N2 - Aims: Randomized data on the efficacy/safety of cardiac resynchronization therapy with vs. without defibrillator (CRT-D,-P) in heart failure with reduced ejection fraction (HFrEF) are scarce. We aimed to evaluate survival associated with use of CRT-D vs. CRT-P in a contemporary cohort with HFrEF. Methods and results: Patients from Swedish HF Registry treated with CRT-D/CRT-P and fulfilling criteria for primary prevention defibrillator use were included. Logistic regression was used to evaluate predictors of CRT-D non-use. All-cause mortality was compared in CRT-D vs. CRT-P by Cox regression in a 1: 1 propensity-score-matched cohort. Of 1988 patients with CRT, 1108 (56%) had CRT-D and 880 (44%) CRT-P. Older age, higher ejection fraction (EF), female sex, and the lack of referral to HF nurse-led outpatient clinic were major determinants of CRT-D non-use. After matching, 645 CRT-D patients were compared with 645 with CRT-P. The CRT-D use was associated with lower 1- A nd 3-year all-cause mortality [hazard ratio (HR):0.76, 95% confidence interval (CI):0.58-0.98; HR: 0.82, 95% CI: 0.68-0.99, respectively]. Results were consistent in all pre-specified subgroups except for CRT-D use being associated with lower 3-year mortality in patients with an EF < 30% but not in those with an EF ≥ 30% (HR: 0.73, 95% CI: 0.59-0.89 and HR: 1.24, 95% CI: 0.83-1.85, respectively; P-interaction = 0.02). Conclusion: In a contemporary HFrEF cohort, CRT-D was associated with lower mortality compared with CRT-P. The CRT-D use was less likely in older patients, females, and in patients not referred to HF nurse-led outpatient clinic. Our findings support the use of CRT-D vs. CRT-P in HFrEF, in particular with severely reduced EF.
AB - Aims: Randomized data on the efficacy/safety of cardiac resynchronization therapy with vs. without defibrillator (CRT-D,-P) in heart failure with reduced ejection fraction (HFrEF) are scarce. We aimed to evaluate survival associated with use of CRT-D vs. CRT-P in a contemporary cohort with HFrEF. Methods and results: Patients from Swedish HF Registry treated with CRT-D/CRT-P and fulfilling criteria for primary prevention defibrillator use were included. Logistic regression was used to evaluate predictors of CRT-D non-use. All-cause mortality was compared in CRT-D vs. CRT-P by Cox regression in a 1: 1 propensity-score-matched cohort. Of 1988 patients with CRT, 1108 (56%) had CRT-D and 880 (44%) CRT-P. Older age, higher ejection fraction (EF), female sex, and the lack of referral to HF nurse-led outpatient clinic were major determinants of CRT-D non-use. After matching, 645 CRT-D patients were compared with 645 with CRT-P. The CRT-D use was associated with lower 1- A nd 3-year all-cause mortality [hazard ratio (HR):0.76, 95% confidence interval (CI):0.58-0.98; HR: 0.82, 95% CI: 0.68-0.99, respectively]. Results were consistent in all pre-specified subgroups except for CRT-D use being associated with lower 3-year mortality in patients with an EF < 30% but not in those with an EF ≥ 30% (HR: 0.73, 95% CI: 0.59-0.89 and HR: 1.24, 95% CI: 0.83-1.85, respectively; P-interaction = 0.02). Conclusion: In a contemporary HFrEF cohort, CRT-D was associated with lower mortality compared with CRT-P. The CRT-D use was less likely in older patients, females, and in patients not referred to HF nurse-led outpatient clinic. Our findings support the use of CRT-D vs. CRT-P in HFrEF, in particular with severely reduced EF.
KW - Cardiac resynchronization therapy
KW - Heart failure
KW - Heart failure with reduced ejection fraction
KW - Implantable cardioverter-defibrillator
KW - Primary prevention
KW - Swedish Heart Failure Registry
UR - http://www.scopus.com/inward/record.url?scp=85123389720&partnerID=8YFLogxK
U2 - 10.1093/europace/euab233
DO - 10.1093/europace/euab233
M3 - Article
C2 - 34486653
SN - 1099-5129
VL - 24
SP - 48
EP - 57
JO - Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
JF - Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
IS - 1
ER -