Skip to main navigation Skip to search Skip to main content

Capture of circulatory endothelial progenitor cells and accelerated re-endothelialization of a bio-engineered stent in human ex vivo shunt and rabbit denudation model

  • Katarína Larsen
  • , Caroline Cheng
  • , Dennie Tempel
  • , Sherry Parker
  • , Saami Yazdani
  • , Wijnand K den Dekker
  • , Jaco H Houtgraaf
  • , Renate de Jong
  • , Stijn Swager-ten Hoor
  • , Erik Ligtenberg
  • , Stephen R Hanson
  • , Steve Rowland
  • , Frank Kolodgie
  • , Patrick W Serruys
  • , Renu Virmani
  • , Henricus J Duckers

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

AIMS: The Genous™ Bio-engineered R™ stent (GS) aims to promote vascular healing by capture of circulatory endothelial progenitor cells (EPCs) to the surface of the stent struts, resulting in accelerated re-endothelialization. Here, we assessed the function of the GS in comparison to bare-metal stent (BMS), when exposed to the human and animal circulation.

METHODS AND RESULTS: First, 15 patients undergoing coronary angiography received an extracorporeal femoral arteriovenous (AV) shunt containing BMS and GS. Macroscopical mural thrombi were observed in BMS, whereas GS remained visibly clean. Confocal and scanning electron microscopic (SEM) analysis of GS showed an increase in strut coverage. Quantitative polymerase chain reaction (qPCR) analysis of captured cells on the GS demonstrated increased expression of endothelial markers KDR/VEGFR2 and E-selectin, and a decrease in pro-thrombogenic markers tissue factor pathway inhibitor and plasminogen activator inhibitor-1 compared with BMS. Secondly, a similar primate AV shunt model was used to validate these findings and occlusion of BMS was observed, while GS remained patent, as demonstrated by live imaging of indium-labelled platelets. Thirdly, in an in vitro cell-capture assay, GS struts showed increased coverage by EPCs, whereas monocyte coverage remained similar to BMS. Finally, the assessment of re-endothelialization was studied in a rabbit denudation model. Twenty animals received BMS and GS in the aorta and iliac arteries for 7 days. Scanning electron microscopic analysis showed a trend towards increased strut coverage, confirmed by qPCR analysis revealing increased levels of endothelial markers (Tie2, CD34, PCD31, and P-selectin) in GS.

CONCLUSION: In this proof-of-concept study, we have demonstrated that the bio-engineered EPC-capture stent, Genous™ R™ stent, is effective in EPC capture, resulting in accelerated re-endothelialization and reduced thrombogenicity.

Original languageEnglish
Pages (from-to)120-8
Number of pages9
JournalEuropean Heart Journal
Volume33
Issue number1
DOIs
Publication statusPublished - Jan 2012

Keywords

  • Aged
  • Angioplasty, Balloon, Coronary
  • Animals
  • Antigens, CD34
  • Arteriovenous Shunt, Surgical
  • Bioengineering
  • Biomarkers
  • Cardiac Catheterization
  • Coronary Artery Disease
  • Coronary Restenosis
  • Cytokines
  • Disease Models, Animal
  • Endothelial Cells
  • Endothelium, Vascular
  • Female
  • Graft Occlusion, Vascular
  • Humans
  • Leukocytes, Mononuclear
  • Male
  • Microscopy, Electron
  • Middle Aged
  • Papio
  • Platelet Adhesiveness
  • Rabbits
  • Stem Cells
  • Stents

Fingerprint

Dive into the research topics of 'Capture of circulatory endothelial progenitor cells and accelerated re-endothelialization of a bio-engineered stent in human ex vivo shunt and rabbit denudation model'. Together they form a unique fingerprint.

Cite this