Automatic measurement of short-term variability of repolarization to indicate ventricular arrhythmias in a porcine model of cardiac ischaemia

Vera Loen, Agnieszka Smoczynska, Alfonso Aranda Hernandez, Coert O S Scheerder, Britt H R van der Linde, Henriëtte D M Beekman, Aina Cervera-Barea, Gerard J J Boink, Joost P G Sluijter, Marcel A G van der Heyden*, Mathias Meine, Marc A Vos

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

5 Downloads (Pure)

Abstract

AIMS: An automated method for determination of short-term variability (STV) of repolarization on intracardiac electrograms (STV-ARIauto) has previously been developed for arrhythmic risk monitoring by cardiac implantable devices, and has proved effective in predicting ventricular arrhythmias (VA) and guiding preventive high-rate pacing (HRP) in a canine model. Current study aimed to assess (i) STV-ARIauto in relation to VA occurrence and secondarily (ii-a) to confirm the predictive capacity of STV from the QT interval and (ii-b) explore the effect of HRP on arrhythmic outcomes in a porcine model of acute myocardial infarction (MI).

METHODS AND RESULTS: Myocardial infarction was induced in 15 pigs. In 7/15 pigs, STV-QT was assessed at baseline, occlusion, 1 min before VA, and just before VA. Eight of the 15 pigs were additionally monitored with an electrogram catheter in the right ventricle, underwent echocardiography at baseline and reperfusion, and were randomized to paced or control group. Paced group received atrial pacing at 20 beats per min faster than sinus rhythm 1 min after occlusion. Short-term variability increased prior to VA in both STV modalities. The percentage change in STV from baseline to successive timepoints correlated well between STV-QT and STV-ARIauto. High-rate pacing did not improve arrhythmic outcomes and was accompanied by a stronger decrease in ejection fraction.

CONCLUSION: STV-ARIauto values increase before VA onset, alike STV-QT in a porcine model of MI, indicating imminent arrhythmias. This highlights the potential of automatic monitoring of arrhythmic risk by cardiac devices through STV-ARIauto and subsequently initiates preventive strategies. Continuous HRP during onset of acute MI did not improve arrhythmic outcomes.

Original languageEnglish
Article numbereuad341
JournalEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
Volume25
Issue number11
DOIs
Publication statusPublished - 1 Nov 2023

Keywords

  • Automatic measurement
  • Cardiac ischaemia
  • Intracardiac electrogram
  • Risk monitoring
  • Short-term variability of repolarization
  • Translational research
  • Ventricular arrhythmias

Fingerprint

Dive into the research topics of 'Automatic measurement of short-term variability of repolarization to indicate ventricular arrhythmias in a porcine model of cardiac ischaemia'. Together they form a unique fingerprint.

Cite this