TY - JOUR
T1 - Anastomotic leakage following robot-assisted minimally invasive esophagectomy (RAMIE)
T2 - which anastomosis should be preferred?
AU - Milone, Marco
AU - Kooij, Cezanne D
AU - Manigrasso, Michele
AU - Goense, Lucas
AU - van Det, Marc J
AU - Kouwenhoven, Ewout A
AU - Gisbertz, Suzanne S
AU - Müller, Beat P
AU - Lingohr, Philipp
AU - Fujita, Takeo
AU - Fuchs, Hans F
AU - Bruns, Christiane J
AU - Krauss, Dolores T
AU - Haveman, Jan W
AU - van Etten, Boudewijn
AU - Perez, Daniel
AU - Egberts, Jan-Hendrik
AU - Turner, Paul
AU - Piessen, Guillaume
AU - Benedix, Frank
AU - Grimminger, Peter P
AU - Bellaio, Luca
AU - Lozanovski, Vladimir J
AU - Ferrari, Giovanni
AU - Mourregot, Anne
AU - Rouanet, Philippe
AU - Hölzen, Jens-Peter
AU - Juratli, Mazen A
AU - Pascher, Andreas
AU - Immanuel, Arul
AU - Luketich, James D
AU - Baker, Nicholas
AU - van Boxel, Gijs I
AU - Harustiak, Tomas
AU - Li, Hecheng
AU - Hubka, Michal
AU - Li, Zhigang
AU - Strignano, Paolo
AU - van Hillegersberg, Richard
AU - Ruurda, Jelle P
N1 - Publisher Copyright:
© The Author(s) 2025.
PY - 2025/9
Y1 - 2025/9
N2 - Background: The optimal technique for intrathoracic esophagogastric anastomosis in esophagectomy remains undetermined. This study evaluates different anastomotic techniques in robot-assisted minimally invasive esophagectomy (RAMIE) and their impact on anastomotic leakage rates. Materials and Methods: This observational, retrospective, comparative cohort study analyzed data obtained from the Upper GI International Robotic Association (UGIRA) Esophageal Registry. All consecutive patients with a histologically proven esophageal malignancy who underwent RAMIE with intrathoracic esophagogastrostomy were included. The anastomotic technique was performed based on the clinical judgement and expertise of each individual surgeon. For comparison, the four most common techniques were included: circular end-to-side, linear side-to-side, handsewn end-to-side, and handsewn end-to-end. The primary endpoint of this study was the occurrence of anastomotic leakage, defined by the Esophagectomy Complications Consensus Group as a full-thickness gastrointestinal defect involving the esophagus, anastomosis, staple line, or conduit, regardless of its presentation or method of identification. Results: Between 2016 and September 2023, 1518 patients were included. Univariable analysis demonstrated that the linear stapled side-to-side anastomosis was associated with the lowest anastomotic leakage rate (14.0%), while the handsewn end-to-end anastomosis had the highest (32.8%) (p < 0.001). The anastomotic leakage rates for circular end-to-side and handsewn end-to-side anastomoses were 19.4% and 26.9%, respectively. Multivariable analysis confirmed that anastomotic technique was independently associated with anastomotic leakage. Specifically, handsewn anastomoses were associated with a higher risk of anastomotic leakage for both end-to-side (OR 1.675, 95% CI 1.195–2.348, p = 0.003) and end-to-end (OR 2.181, 95% CI 1.403–3.390, p < 0.001) techniques compared to circular end-to-side anastomoses. Conclusions: In RAMIE, linear side-to-side and circular end-to-side stapled anastomoses are associated with lower anastomotic leakage rates compared to handsewn techniques. While acknowledging the multifactorial complexity of anastomotic leakage, these findings favor the use of mechanical stapling in clinical practice.
AB - Background: The optimal technique for intrathoracic esophagogastric anastomosis in esophagectomy remains undetermined. This study evaluates different anastomotic techniques in robot-assisted minimally invasive esophagectomy (RAMIE) and their impact on anastomotic leakage rates. Materials and Methods: This observational, retrospective, comparative cohort study analyzed data obtained from the Upper GI International Robotic Association (UGIRA) Esophageal Registry. All consecutive patients with a histologically proven esophageal malignancy who underwent RAMIE with intrathoracic esophagogastrostomy were included. The anastomotic technique was performed based on the clinical judgement and expertise of each individual surgeon. For comparison, the four most common techniques were included: circular end-to-side, linear side-to-side, handsewn end-to-side, and handsewn end-to-end. The primary endpoint of this study was the occurrence of anastomotic leakage, defined by the Esophagectomy Complications Consensus Group as a full-thickness gastrointestinal defect involving the esophagus, anastomosis, staple line, or conduit, regardless of its presentation or method of identification. Results: Between 2016 and September 2023, 1518 patients were included. Univariable analysis demonstrated that the linear stapled side-to-side anastomosis was associated with the lowest anastomotic leakage rate (14.0%), while the handsewn end-to-end anastomosis had the highest (32.8%) (p < 0.001). The anastomotic leakage rates for circular end-to-side and handsewn end-to-side anastomoses were 19.4% and 26.9%, respectively. Multivariable analysis confirmed that anastomotic technique was independently associated with anastomotic leakage. Specifically, handsewn anastomoses were associated with a higher risk of anastomotic leakage for both end-to-side (OR 1.675, 95% CI 1.195–2.348, p = 0.003) and end-to-end (OR 2.181, 95% CI 1.403–3.390, p < 0.001) techniques compared to circular end-to-side anastomoses. Conclusions: In RAMIE, linear side-to-side and circular end-to-side stapled anastomoses are associated with lower anastomotic leakage rates compared to handsewn techniques. While acknowledging the multifactorial complexity of anastomotic leakage, these findings favor the use of mechanical stapling in clinical practice.
KW - Anastomotic leakage
KW - Anastomotic technique
KW - Minimally invasive esophagectomy
KW - RAMIE
UR - https://www.scopus.com/pages/publications/105013795355
U2 - 10.1007/s00464-025-11977-x
DO - 10.1007/s00464-025-11977-x
M3 - Article
C2 - 40640625
SN - 0930-2794
VL - 39
SP - 5604
EP - 5612
JO - Surgical endoscopy
JF - Surgical endoscopy
IS - 9
ER -