TY - JOUR
T1 - Analysis of C-reactive protein from finger stick dried blood spot to predict high risk of cardiovascular disease
AU - Schakelaar, Michael Y.
AU - Kemperman, Hans
AU - Schoneveld, Arjan H.
AU - Hoefer, Imo E.
AU - Tiel Groenestege, Wouter M.
N1 - Funding Information:
This work was supported by a grant of Siemens Healthineers. The funder had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Publisher Copyright:
© 2023, The Author(s).
PY - 2023/2/13
Y1 - 2023/2/13
N2 - C-reactive protein (CRP) is an acute-phase protein involved in inflammation. Furthermore, CRP is an important biomarker used in diagnostics to predict risk of cardiovascular disease (CVD) in addition to monitoring bacterial and viral infections. To measure plasma CRP, venipuncture is still necessitated and has to be performed by trained phlebotomists. As a solution, dried blood spots (DBS) are used for minimally invasive at-home sampling of blood and can be send to diagnostic laboratories by regular mail. In this study, we included 53 patients that presented to the outpatient clinic of the University Medical Center Utrecht. Capillary finger stick was used to spot blood on a filter paper card and allowed to dry. After extraction of DBS, CRP was analyzed on an automated high-throughput chemistry analyzer. Additional validation steps regarding stability, effect of hematocrit, precision, and limits of blank and quantitation were conducted according to corresponding Clinical and Laboratory Standards Institute standards. An excellent regression analysis of R2 (95% confidence interval) = 0.986 (0.982–0.989) was found. This enabled correct classification for high CVD risk of all 25 cases with sensitivity (95% CI) of 1.00 (1.00–1.00) and specificity (95% CI) of 0.96 (0.89–1.03) and correct diagnosis of inflammation of 12/13 cases with sensitivity (95% CI) of 0.92 (0.77–1.07) and specificity (95% CI) of 1.00 (1.00–1.00). Furthermore, CRP was found to be stable for 31 days and observed hematocrit variation amongst patients was clinically acceptable. CRP from DBS can be accurately measured on an automated high-throughput chemistry analyzer and used to diagnose inflammation and classify high CVD risk. This method enables individuals to engage in at-home sampling of blood on DBS for (tele)diagnostics, screening programs, patient follow-up, and medication management.
AB - C-reactive protein (CRP) is an acute-phase protein involved in inflammation. Furthermore, CRP is an important biomarker used in diagnostics to predict risk of cardiovascular disease (CVD) in addition to monitoring bacterial and viral infections. To measure plasma CRP, venipuncture is still necessitated and has to be performed by trained phlebotomists. As a solution, dried blood spots (DBS) are used for minimally invasive at-home sampling of blood and can be send to diagnostic laboratories by regular mail. In this study, we included 53 patients that presented to the outpatient clinic of the University Medical Center Utrecht. Capillary finger stick was used to spot blood on a filter paper card and allowed to dry. After extraction of DBS, CRP was analyzed on an automated high-throughput chemistry analyzer. Additional validation steps regarding stability, effect of hematocrit, precision, and limits of blank and quantitation were conducted according to corresponding Clinical and Laboratory Standards Institute standards. An excellent regression analysis of R2 (95% confidence interval) = 0.986 (0.982–0.989) was found. This enabled correct classification for high CVD risk of all 25 cases with sensitivity (95% CI) of 1.00 (1.00–1.00) and specificity (95% CI) of 0.96 (0.89–1.03) and correct diagnosis of inflammation of 12/13 cases with sensitivity (95% CI) of 0.92 (0.77–1.07) and specificity (95% CI) of 1.00 (1.00–1.00). Furthermore, CRP was found to be stable for 31 days and observed hematocrit variation amongst patients was clinically acceptable. CRP from DBS can be accurately measured on an automated high-throughput chemistry analyzer and used to diagnose inflammation and classify high CVD risk. This method enables individuals to engage in at-home sampling of blood on DBS for (tele)diagnostics, screening programs, patient follow-up, and medication management.
UR - http://www.scopus.com/inward/record.url?scp=85147898616&partnerID=8YFLogxK
U2 - 10.1038/s41598-023-27522-6
DO - 10.1038/s41598-023-27522-6
M3 - Article
C2 - 36781868
AN - SCOPUS:85147898616
SN - 2045-2322
VL - 13
JO - Scientific Reports
JF - Scientific Reports
IS - 1
M1 - 2515
ER -