Allura clarity radiation dose-reduction technology in the hybrid operating room during endovascular aneurysm repair

Quirina M B De Ruiter*, Frans L. Moll, Crystel M. Gijsberts, Joost A. Van Herwaarden

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Purpose: To evaluate the effect of radiation dose reduction with the Allura ClarityIQ image processing technology for fixed C-arms in comparison with a mobile C-arm and an Allura fixed C-arm without ClarityIQ technology during endovascular aneurysm repair (EVAR) procedures. Methods: Radiation dose data from 85 patients (mean age 74.2±7.8 years; 68 men) undergoing EVAR with mobile and fixed C-arm fluoroscopy were retrospectively analyzed. The radiation dose parameters included the kerma area product (KAP), fluoroscopic time (FT), and number of digital subtraction angiography (DSA) frames (FrDSA). KAPtotal consisted of KAPfluoro (KAP for fluoroscopic imaging) and KAPDSA (KAP for DSA and single shots). Linear regression analysis was used to explore differences in the association of KAP with the FT, FrDSA, and body mass index (BMI) among the 3 C-arms. Results: The mean KAPtotal values for mobile, Allura C-arm, and AlluraClarity C-arm for noncomplex EVARs were 56±39, 245±142, and 157±120 Gycm2 (p2 (pfluoro tripled when the mobile C-arm was replaced by the fixed C-arm. There were no significant differences in the KAPfluoro adjusted for the FT between Allura and AlluraClarity (p=0.69). However, there was a major 61% reduction in KAPDSA from 1.36 Gycm2 per DSA frame for Allura to 0.54 Gycm2 per DSA frame with AlluraClarity (p=0.03). For the mobile C-arm, BMI was not associated with KAP (p=0.13). The associations of BMI with KAPfluoro and KAPDSA were significant for both fixed C-arms but were more robust for Allura compared to AlluraClarity (p=0.02 for KAPfluoro and pDSA). Conclusion: Changing a mobile C-arm for a fixed C-arm in a hybrid operating suite increased the average intraoperative dose during EVAR. Upgrading the Allura fixed C-arm with ClarityIQ technology resulted in a 61% reduction in the radiation per DSA frame.

Original languageEnglish
Pages (from-to)130-138
Number of pages9
JournalJournal of Endovascular Therapy
Volume23
Issue number1
DOIs
Publication statusPublished - 1 Feb 2016

Keywords

  • Abdominal aortic aneurysm
  • C-arm image intensifier
  • Digital subtraction angiography
  • Dose reduction
  • Endovascular aneurysm repair
  • Fluoroscopy
  • Imaging technology
  • Kerma area product
  • Radiation dose
  • Radiation physics