Skip to main navigation Skip to search Skip to main content

Advances in sorbent peritoneal dialysis technologies: A narrative review

  • Susan Bríd McGrath*
  • , Pauline Kosalka
  • , Marjorie W. Foo
  • , Htay Htay
  • , Edwina A. Brown
  • , Karin G.F. Gerritsen
  • , Olof Heimbürger
  • , Arsh K. Jain
  • *Corresponding author for this work

Research output: Contribution to journal › Review article › peer-review

3 Downloads (Pure)

Abstract

Sorbent peritoneal dialysis (SPD) removes a tidal volume of spent dialysate, passing it through sorbent layers before infusing replacement electrolytes and dextrose to regenerate dialysate. We examine the five devices using SPD in published literature, reviewing their design, dialysis clearance, and ultrafiltration (UF) capacity—Automated Wearable Artificial Kidney (AWAK), now called Viva Kompact since 2024, Carry Life System PD/Carry Life UF, Wearable Artificial Kidney (WEAKID), Vicenza Wearable Artificial Kidney (ViWAK), and Renart-PD. Carry Life devices and Viva Kompact have reported on human trials, WEAKID and Renart-PD on animal studies, while ViWAK has published in vitro data. All devices have published data on dialysis clearance capabilities. WEAKID and Carry Life PD achieved a high dialysate:plasma concentration gradient for small solutes. Viva Kompact and Renart-PD reported stable or lower serum concentrations of urea, creatinine, phosphate, and β2-microglogulin following treatments. ViWAK demonstrated removal of creatinine, B2 microglobulin, and angiogenin to <10% of pre-treatment levels. UF capacity remains unknown for many devices. In human trials, Carry Life UF has achieved 863 mL UF in a 5-h treatment with the addition of 20 g/h of glucose to 1.5% dextrose dialysate. Viva Kompact has demonstrated 877 mL UF in a 9-h treatment using 1.5% dextrose dialysate in an animal model, comparable to 10-h APD, with the addition of 6.6 g/h glucose. Both devices have demonstrated improved UF per gram of glucose used. The expected use of these devices varies greatly, from an adjunct to currently available treatments to a complete replacement for current modalities. Large-scale, human studies are needed to determine their role in the future of PD delivery.

Original languageEnglish
Pages (from-to)499-509
Number of pages11
JournalPeritoneal Dialysis International
Volume46
Issue number5
Early online date18 Sept 2025
DOIs
Publication statusPublished - Sept 2026

Keywords

  • artificial kidney
  • chronic kidney disease
  • peritoneal dialysis
  • Sorbent
  • wearables

Fingerprint

Dive into the research topics of 'Advances in sorbent peritoneal dialysis technologies: A narrative review'. Together they form a unique fingerprint.

Cite this