TY - JOUR
T1 - A multipurpose, adolescent idiopathic scoliosis-specific, short MRI protocol
T2 - A feasibility study in volunteers
AU - Shcherbakova, Yulia M.
AU - Lafranca, Peter P.G.
AU - Foppen, Wouter
AU - van der Velden, Tijl A.
AU - Nievelstein, Rutger A.J.
AU - Castelein, Rene M.
AU - Ito, Keita
AU - Seevinck, Peter R.
AU - Schlosser, Tom P.C.
N1 - Publisher Copyright:
© 2024 The Authors
PY - 2024/8
Y1 - 2024/8
N2 - Introduction: Visualization of scoliosis typically requires ionizing radiation (radiography and CT) to visualize bony anatomy. MRI is often additionally performed to screen for neural axis abnormalities. We propose a 14-minutes radiation-free scoliosis-specific MRI protocol, which combines MRI and MRI-based synthetic CT images to visualize soft and osseous structures in one examination. We assess the ability of the protocol to visualize landmarks needed to detect 3D patho-anatomical changes, screen for neural axis abnormalities, and perform surgical planning and navigation. Methods: 18 adult volunteers were scanned on 1.5 T MR-scanner using 3D T2-weighted and synthetic CT sequences. A predefined checklist of relevant landmarks was used for the parameter assessment by three readers. Parameters included Cobb angles, rotation, torsion, segmental height, area and centroids of Nucleus Pulposus and Intervertebral Disc. Precision, reliability and agreement between the readers measurements were evaluated. Results: 91 % of Likert-based questions scored ≥ 4, indicating moderate to high confidence. Precision of 3D dot positioning was 1.0 mm. Precision of angle measurement was 0.6° (ICC 0.98). Precision of vertebral and IVD height measurements was 0.4 mm (ICC 0.99). Precision of area measurement for NP was 8 mm2 (ICC 0.55) and for IVD 18 mm2 (ICC 0.62) for IVD. Precision of centroid measurement for NP was 1.3 mm (ICC 0.88–0.92) and for IVD 1.1 mm (ICC 0.88–91). Conclusions: The proposed MRI protocol with synthetic CT reconstructions, has high precision, reliability and agreement between the readers for multiple scoliosis-specific measurements. It can be used to study scoliosis etiopathogenesis and to assess 3D spinal morphology.
AB - Introduction: Visualization of scoliosis typically requires ionizing radiation (radiography and CT) to visualize bony anatomy. MRI is often additionally performed to screen for neural axis abnormalities. We propose a 14-minutes radiation-free scoliosis-specific MRI protocol, which combines MRI and MRI-based synthetic CT images to visualize soft and osseous structures in one examination. We assess the ability of the protocol to visualize landmarks needed to detect 3D patho-anatomical changes, screen for neural axis abnormalities, and perform surgical planning and navigation. Methods: 18 adult volunteers were scanned on 1.5 T MR-scanner using 3D T2-weighted and synthetic CT sequences. A predefined checklist of relevant landmarks was used for the parameter assessment by three readers. Parameters included Cobb angles, rotation, torsion, segmental height, area and centroids of Nucleus Pulposus and Intervertebral Disc. Precision, reliability and agreement between the readers measurements were evaluated. Results: 91 % of Likert-based questions scored ≥ 4, indicating moderate to high confidence. Precision of 3D dot positioning was 1.0 mm. Precision of angle measurement was 0.6° (ICC 0.98). Precision of vertebral and IVD height measurements was 0.4 mm (ICC 0.99). Precision of area measurement for NP was 8 mm2 (ICC 0.55) and for IVD 18 mm2 (ICC 0.62) for IVD. Precision of centroid measurement for NP was 1.3 mm (ICC 0.88–0.92) and for IVD 1.1 mm (ICC 0.88–91). Conclusions: The proposed MRI protocol with synthetic CT reconstructions, has high precision, reliability and agreement between the readers for multiple scoliosis-specific measurements. It can be used to study scoliosis etiopathogenesis and to assess 3D spinal morphology.
KW - Adolescent Idiopathic Scoliosis
KW - Multipurpose MRI-protocol
KW - Radiation-free
KW - Scoliosis-specific
KW - Short MRI-protocol
KW - Spinal navigation
UR - http://www.scopus.com/inward/record.url?scp=85195363459&partnerID=8YFLogxK
U2 - 10.1016/j.ejrad.2024.111542
DO - 10.1016/j.ejrad.2024.111542
M3 - Article
AN - SCOPUS:85195363459
SN - 0720-048X
VL - 177
JO - European Journal of Radiology
JF - European Journal of Radiology
M1 - 111542
ER -