TY - JOUR
T1 - A diffusion MRI model for random walks confined on cylindrical surfaces
T2 - towards non-invasive quantification of myelin sheath radius
AU - Canales-Rodríguez, Erick J.
AU - Tax, Chantal M.W.
AU - Fischi-Gomez, Elda
AU - Jones, Derek K.
AU - Thiran, Jean Philippe
AU - Rafael-Patiño, Jonathan
N1 - Publisher Copyright:
Copyright © 2025 Canales-Rodríguez, Tax, Fischi-Gomez, Jones, Thiran and Rafael-Patiño.
PY - 2025/3/6
Y1 - 2025/3/6
N2 - Introduction: Quantifying the myelin sheath radius of myelinated axons in vivo is important for understanding, diagnosing, and monitoring various neurological disorders. Despite advancements in diffusion MRI (dMRI) microstructure techniques, there are currently no models specifically designed to estimate myelin sheath radii. Methods: This proof-of-concept theoretical study presents two novel dMRI models that characterize the signal from water diffusion confined to cylindrical surfaces, approximating myelin water diffusion. We derive their spherical mean signals, eliminating fiber orientation and dispersion effects for convenience. These models are further extended to account for multiple concentric cylinders, mimicking the layered structure of myelin. Additionally, we introduce a method to convert histological distributions of axonal inner radii from the literature into myelin sheath radius distributions. We also derive analytical expressions to estimate the effective myelin sheath radius expected from these distributions. Results and Discussion: Monte Carlo (MC) simulations conducted in cylindrical and spiral geometries validate the models. These simulations demonstrate agreement with analytical predictions. Furthermore, we observe significant correlations between the effective radii derived from histological distributions and those obtained by fitting the dMRI signal to a single-cylinder model. These models may be integrated with existing multi-compartment dMRI techniques, opening the door to non-invasive in vivo assessments of myelin sheath radii. Such assessments would require MRI scanners equipped with strong diffusion gradients, allowing measurements with short echo times. Further work is required to validate the technique with real dMRI data and histological measurements.
AB - Introduction: Quantifying the myelin sheath radius of myelinated axons in vivo is important for understanding, diagnosing, and monitoring various neurological disorders. Despite advancements in diffusion MRI (dMRI) microstructure techniques, there are currently no models specifically designed to estimate myelin sheath radii. Methods: This proof-of-concept theoretical study presents two novel dMRI models that characterize the signal from water diffusion confined to cylindrical surfaces, approximating myelin water diffusion. We derive their spherical mean signals, eliminating fiber orientation and dispersion effects for convenience. These models are further extended to account for multiple concentric cylinders, mimicking the layered structure of myelin. Additionally, we introduce a method to convert histological distributions of axonal inner radii from the literature into myelin sheath radius distributions. We also derive analytical expressions to estimate the effective myelin sheath radius expected from these distributions. Results and Discussion: Monte Carlo (MC) simulations conducted in cylindrical and spiral geometries validate the models. These simulations demonstrate agreement with analytical predictions. Furthermore, we observe significant correlations between the effective radii derived from histological distributions and those obtained by fitting the dMRI signal to a single-cylinder model. These models may be integrated with existing multi-compartment dMRI techniques, opening the door to non-invasive in vivo assessments of myelin sheath radii. Such assessments would require MRI scanners equipped with strong diffusion gradients, allowing measurements with short echo times. Further work is required to validate the technique with real dMRI data and histological measurements.
KW - diffusion MRI
KW - Monte Carlo simulations
KW - myelin sheath radius
KW - myelin water
KW - white matter microstructure
UR - http://www.scopus.com/inward/record.url?scp=105000529586&partnerID=8YFLogxK
U2 - 10.3389/fphy.2025.1516630
DO - 10.3389/fphy.2025.1516630
M3 - Article
AN - SCOPUS:105000529586
SN - 2296-424X
VL - 13
JO - Frontiers in Physics
JF - Frontiers in Physics
M1 - 1516630
ER -